Efficacy of Micromesh-Covered Stents in Carotid Artery Stenting

Most literature, old and recent, associates carotid artery stenting with a higher rate of stroke (although minor) when compared with carotid endarterectomy during the acute period. However, 30-day outcomes of angioplasty and surgery are comparable.

balon_farmacologico_reestenosis_instrastentMany technical advancements, including new stent designs and different cerebral protection mechanisms, have improved the outcomes of angioplasty in clinical terms as well as in new cerebral magnetic resonance imaging scans.

 

This single-center study assesses the new CGuard carotid stent, a nitinol stent covered by a closed-cell (<180 µm) polyethylene terephthalate (PET) micromesh designed to prevent cerebral embolic events caused by plaque protrusion. This stent applies the technology behind the MGuard device, designed for coronary arteries and tested in the Master trial as published in CircCardiovascInterv 2015.


Read also: Mitral Valve Repair with MitraClip Is Safe in High-Risk Patients”.


Eighty-two consecutive patients who underwent carotid artery stenting with CGuard were enrolled and assessed regarding both clinical and imaging endpoints.

 

Among them, 19% were asymptomatic at the time the procedure was performed and mean stenosis was 81.4 ± 4.9%.

 

There was technical success in 100% of all symptomatic patients, and in 98.5% of all asymptomatic patients due to the occurrence of one acute stent thrombosis event 4 hours after the procedure, which was associated with a minor stroke. In the immediate post-operative period (30 days), there were no events.


Read also: Important Study Detects Radiation-Induced DNA Damage in Operators After an Endovascular Procedure”.


New ischemic brain lesions were observed during a diffusion weighted magnetic resonance imaging in 23.8% of patients, and the average lesion volume per patient was 0.039 ± 0.025 cm³.

 

Conclusion

The technical and clinical success of this new device turns it into a safe and effective option for the treatment of carotid lesions, regardless of aortic arch anatomy.

 

Editorial

Carotid artery stenting is sometimes a technically demanding procedure, which means that the existence of a learning curve is undeniable.

 

Many early trials on this subject reporting suboptimal outcomes for angioplasty were criticized for the inexperience of participating operators, and Dr. Brahmajee’s work published in JAMA proves the association between inexperience and mortality.

 

This study was carried out in a single center with a single operator who takes part in over 85 carotid artery stenting procedures per year. Undoubtedly, procedures within this study were performed by an expert, but this fact impacts negatively on the external validity and reproducibility of this work.

 

Original title: Safety and Efficacy of the New Micromesh-Covered Stent CGuard in Patients Undergoing Carotid Artery Stenting: Early Experience from a Single Centre.

Reference: Renato Casana et al. Eur J Vasc Endovasc Surg (2017), article in press.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

TCT 2024 | SIRONA: Randomized Study Comparing Sirolimus-Coated vs Paclitaxel-Coated Balloon Angioplasty in Femoropopliteal Disease

This prospective, randomized, multicenter, investigator-initiated non-inferiority study compared the use of sirolimus-coated balloon (MagicTouch) vs paclitaxel-coated balloon in endovascular treatment.  The primary objective was to...

TCT 2024 | PEERLESS: Mechanical Thrombectomy with FlowTriever vs Catheter-Directed Thrombolysis in Intermediate Risk PTE

Pulmonary embolism (PE) continues to be the third cause of cardiovascular mortality. The current clinical guidelines recommend anticoagulation in intermediate risk patients presenting right...

Atherosclerotic Renal Artery Stenosis: To Revascularize or Not

At long term, atherosclerotic renal artery stenosis (RAS) can lead to hypertension, chronic kidney disease, and cardiac failure. Historically, these patients have been referred...

Endovascular Management of Chronic TEPH: Is Coronary Management Extrapolatable in This Scenario?

Chronic thromboembolic pulmonary hypertension (CTEPH) is a condition that causes significant functional limitation. Its surgical treatment, known as pulmonary endarterectomy (PEA), has improved the...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

TCT 2024 | FAVOR III EUROPA

The study FAVOR III EUROPA, a randomized trial, included 2,000 patients with chronic coronary syndrome, or stabilized acute coronary syndrome, and intermediate lesions. 1,008...

TCT 2024 | TRISCEND II

This randomized study included 400 patients; 267 were treated with EVOQUE valve and 133 with optimal medical treatment (OMT). After one-year follow-up, there were no...

TCT 2024 – ACCESS-TAVI: Comparing Percutaneous Access Closure Strategies After TAVI

Vascular access complications following transcatheter aortic valve implantation (TAVI) remain common. However, few studies compare vascular access closure methods.  Based on the CHOICE-CLOSURE and MASH...