PERFORMANCE II Trial: Safety and Efficacy of the New NeuroGuard Carotid Stent System

The percutaneous treatment of carotid artery disease through stenting (CAS) for the prevention of cerebrovascular disease has proven to be an effective alternative compared to carotid endarterectomy (CEA) surgery. Various studies have shown no significant differences between both strategies (CAS vs. CEA) in terms of mortality, stroke, or acute myocardial infarction (AMI) within 30 days. However, the incidence of minor stroke remains higher in patients who underwent CAS, despite the use of embolic protection filters.

The NeuroGuard IEP3 carotid stent is a system based on a 6-Fr catheter, composed of a nitinol stent mounted on a semi-compliant balloon and a distal protection filter. The PERFORMANCE I study assessed the use of this system in 67 patients with successful implementation without cerebrovascular events during follow-up.

The objective of the PERFORMANCE II trial, a prospective and multicenter study, was to assess the safety and efficacy of the NeuroGuard IEP3 system in the treatment of severe carotid artery stenosis in a population of patients at high risk of complications after CEA.

Read also: Acute Coronary Syndrome with Multivessel Disease: Best Revascularization Strategy.

The primary endpoint (PE) was the rate of major adverse events (MAE), defined as death, stroke, and AMI within 30 days after the procedure. The secondary endpoint (SE) included procedural success, minor stroke, major stroke, neurological death, and clinically driven target lesion revascularization (TLR).

Results

The trial included a total of 305 patients, with a mean age of 69 years. Most of the subjects were men. Only 20% of patients were considered symptomatic. The mean lesion length was 19 mm, and 34% of the lesions showed severe calcification.

Regarding the PE, at 30 days, four cases of minor stroke (1.3%) were reported, with no records of major stroke. The combined stroke/mortality rate was 1.6%, while the stroke/mortality/AMI rate was 2.3%. At 12 months, the PE had occurred in only 2.8% of patients, with no instances of major stroke, TLR, stent thrombosis, or neurological death.

Conclusion

This study showed a low rate of major adverse events compared to historical evidence, confirming that the NeuroGuard IEP system is a safe, effective, and durable option for the percutaneous treatment of carotid artery disease in patients at high risk of complications from CEA. The 12-month stroke rate of 1.8% is the lowest reported to date for any carotid artery revascularization strategy.

Original Title: The PERFORMANCE II Trial A Prospective Multicenter Investigation of a Novel Carotid Stent System.

Reference: William A. Gray, MD et al JACC Cardiovasc Interv. 2025.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

Dr. Andrés Rodríguez
Dr. Andrés Rodríguez
Member of the Editorial Board of solaci.org

More articles by this author

Supera vs. Eluvia at 3 Years in Severely Calcified Femoropopliteal Lesions

Severe calcification remains one of the main predictors of restenosis and the need for repeat revascularization following endovascular treatment of femoropopliteal disease. In this...

Is abdominal aortic aneurysm screening cost-effective in women?

Although ultrasound screening for abdominal aortic aneurysm (AAA) is a well-established strategy in men over 65 years of age, its value in women remains...

Aneurysm Sac Regression Predicts Better Clinical Outcomes After EVAR?

Aneurysm sac regression following endovascular abdominal aortic aneurysm repair (EVAR) has been proposed as a marker of favorable remodeling and effective aneurysm exclusion. However,...

SPYRAL Program: 3-Year Outcomes in Patients Treated with Renal Denervation

Hypertension is the leading modifiable risk factor for cardiovascular disease and remains a major global health challenge, affecting more than one billion adults worldwide.  Despite...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

UNICORN Technique to Prevent Coronary Obstruction During TAVI: Initial Results From a Multicenter Study

Coronary obstruction is an uncommon but potentially catastrophic complication of transcatheter aortic valve implantation (TAVI), particularly in valve-in-valve procedures, TAV-in-TAV interventions, or in patients...

Supera vs. Eluvia at 3 Years in Severely Calcified Femoropopliteal Lesions

Severe calcification remains one of the main predictors of restenosis and the need for repeat revascularization following endovascular treatment of femoropopliteal disease. In this...

Is IVUS Always Necessary for Left Main Coronary Artery PCI?

Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery is a highly complex procedure because of the large amount of myocardium at...