MRI different injuries post carotid angioplasty versus endarterectomy.

Original title: Characteristics of Ischemic Brain Lesions After Stenting or Endarterectomy for Symptomatic Carotid Artery Stenosis : Results From the International Carotid Stenting Study-Magnetic Resonance Imaging Substudy (ICSS-MRI). Reference: Henrik Gensicke et al. Stroke 2013;44:80-86.

This work is a sub-study using magnetic resonance imaging (MRI) of the International Carotid Stenting Study (ICSS) that randomized carotid angioplasty (CAS) or endarterectomy (CEA) in patients with symptomatic carotid lesions

We analyzed the number of new lesions using MRI by volume, location and subgroups of patients. A total of 231 patients were included (124 patients received CAS and 107 CEA). The proportion of patients with one MRI lesion was 15% for CAS and 8% for CEA, whereas 2 to 5 lesions was 19% versus 5% respectively and with over 5 lesions 16% versus 4% respectively. In the subgroup analysis, relative risk was higher for patients with a systolic pressure below 158 mmHg at the time of randomization, diabetes, hemispheric stroke as index event or left carotid injury.

When analyzing the total injuries in patients, it was identical between CAS and CEA (p = 0.18) since the average size of each lesion in the CAS group was significantly smaller than in the CEA group, (0.02 ml versus 0.08 ml, P <0.0001), which offset the higher number.

Conclusion 

Patients with symptomatic carotid lesions have a greater number of lesions observed by MRI post angioplasty than post endarterectomy but these lesions are significantly smaller.

Editorial Comment:

The highest number of injuries and being smaller in turn with CAS are justified by microemboli during the procedure. Nevertheless, the clinical impact of these small lesions is unknown. In general, it is more likely that small lesions are reversible and silent compared with larger lesions. It needs investigating whether these small lesions may influence cognitive ability. Patients presenting hemispheric stroke had more new lesions with angioplasty than those with transient ischemic attack. However, this difference was not seen with endarterectomy, which may make the latter more secure to treat patients with stroke.

SOLACI.ORG

More articles by this author

Endovascular Treatment of Iliofemoral Disease for the Improvement of Heart Failure with Preserved Ejection Fraction

Peripheral artery disease (PAD) is a significant risk factor in the development of difficult-to-treat conditions, such as heart failure with preserved ejection fraction (HFpEF)....

Chronic Thromboembolic Pulmonary Hypertension: Treatment Outcomes According to a Worldwide Registry

Chronic thromboembolic pulmonary hypertension (CTEPH) is a highly limiting condition that, despite its moderate incidence, significantly impacts patient prognosis and quality of life. The...

Contemporary Outcomes of Acute Limb Ischemia Endovascular Revascularization

Acute limb ischemia (ALI) is a vascular emergency with high mortality rate. It has been defined as a sudden occlusion of limb perfusion compromising...

TCT 2024 | SIRONA: Randomized Study Comparing Sirolimus-Coated vs Paclitaxel-Coated Balloon Angioplasty in Femoropopliteal Disease

This prospective, randomized, multicenter, investigator-initiated non-inferiority study compared the use of sirolimus-coated balloon (MagicTouch) vs paclitaxel-coated balloon in endovascular treatment.  The primary objective was to...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

TricValve Transcatheter Bicaval Valve System for Severe Tricuspid Insufficiency: Events at One Year

TricValve is the first bicaval valve system to obtain CE-Mark approval. This device heterotopic device eliminates tricuspid insufficiency reflux into the venous system, reducing...

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...