Randomized study of bioabsorbable polymer-coated sirolimus-eluting stent: DESSOLVE II protocol results

Original title: Randomised study of a bioabsorbable polymer-coated sirolimus-eluting stent: results of the DESSOLVE II trial. Reference: Wijns W EuroIntervention 2015 Apr 22;10(12):1383-90.

Multicenter, randomized study, which enrolled in 26 centers, a total of 184 patients 2:1 (bioabsorbable polymer-coated sirolimus-eluting stent, (SES) [n = 123] versus zotarolimus-eluting stent (ZES) [n = 61]). All patients were evaluated with quantitative coronary angiography (QCA) immediately after stent implantation and at nine months, while a subgroup of patients in both groups were also subjected to evaluation by optical coherence tomography (OCT).

The primary hypothesis of superiority of the work, is evaluating SES over SLZ in “late lumen loss” (LLL). At nine months hypothesis was fulfilled, showing significant differences in SES in LLL values (0.27 ± 0.46 mm versus 0.58 ± 0.41 mm, p <0.001); the percentage of uncovered stent struts at nine months by OCT was very low in both groups, as well as the number of major events and stent thrombosis, with similar results in both groups. 

Conclusion

DESSOLVE II study demonstrated superiority of SES over SLZ regarding the primary objective, demonstrating a significant reduction in late lumen loss (LLL). Also confirms by OCT that the percentage of coverage stent struts is high in both groups at nine months, with a high safety profile of both stents, with low MACE and stent thrombosis.

Editorial comment

There are several limitations of the study: protocol of small dimensions, with a short follow-up so far (planned follow-up to five years), “single-blind” (in this way can create a selection bias towards injuries to treat), with a percentage of patients who underwent OCT without explaining the criteria why some patients were selected, with a “soft” primary endpoint (LLL). Moreover, the treated lesions were simple lesions (A, B1, B2), being complex injuries an exclusion criterion. Despite all this, the goal of superiority was met with SES, and above all, it was possible to show that the safety profile of the device is at least similar to SLZ, with low percentages and acceptable MACE and stent thrombosis (to nine months SES/SLZ 4.3% versus 6.7% and 0.9% versus 1.7%, respectively). Long-term monitoring is pending to draw major conclusions. 

Courtesy of Santiago F. Coroleu MD
Interventional Cardiologist
Instituto de Cardiología de Santiago del Estero (Argentina).

Dr. Santiago F. Coroleu

More articles by this author

Coronary Perforations and Use of Covered Stents: Safe and Effective Long-Term Strategy?

Coronary perforations remain one of the most serious complications of percutaneous coronary intervention (PCI), especially in cases of Ellis ruptures type III. In these...

Left Main Coronary Artery Disease: Intravascular Imaging-Guided PCI vs. Coronary Artery Bypass Grafting

Multiple randomized clinical trials have demonstrated superior outcomes with coronary artery bypass grafting (CABG) vs. percutaneous coronary intervention (PCI) in patients with left main...

AHA 2025 | OCEAN Study: Anticoagulation vs. Antiplatelet Therapy After Successful Atrial Fibrillation Ablation

After a successful atrial fibrillation (AF) ablation, the need to maintain long-term anticoagulation (AC) remains uncertain, especially considering the very low residual embolic risk...

AHA 2025 | VESALIUS-CV: Evolocumab in High-Cardiovascular-Risk Patients Without Prior MI or Stroke

LDL cholesterol is a well-established factor for cardiovascular disease. Therapy with PCSK9 inhibitors, including evolocumab, has been shown to reduce the risk of cardiovascular...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Coronary Perforations and Use of Covered Stents: Safe and Effective Long-Term Strategy?

Coronary perforations remain one of the most serious complications of percutaneous coronary intervention (PCI), especially in cases of Ellis ruptures type III. In these...

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....