MitraClip Procedure Can Be Performed without General Anesthesia

Courtesy of Dr. Carlos Fava.

Avoiding general anesthesia in intervention procedures has the benefits of faster recovery and shorter hospitalization. This has been already analyzed in the context of TAVR, but not in MitraClip procedures.

Es posible realizar MitraClip sin anestesia general

The present study analyzed 232 patients receiving the MitraClip. 76 of these procedures were done under general anesthesia (32.7%) and 156 under deep sedation (67.3%).


Read also: The SOURCE 3 Confirms the Good Outcomes of the SAPIEN 3 at One Year Followup”.


Populations were similar in age, comorbidities, EuroScore, severity of mitral failure, left and right ventricular function, and renal function.

 

Both strategies saw safe MitraClip implantation, with no difference in number of implanted clips, or residual mitral failure (with low complications rate). Only 2 patients required conversion to general anesthesia. Total procedural time was lower with deep sedation (DS), driven mainly by preparation.

 

Intensive care was shorter with DS (2.6±4.4 vs. 1.5±1.4 p=0.003). However, hospital stay was similar.


Read also: New Study Confirms TAVR Durability at 5 Years”.


At 90 day follow up, both groups improved functional class and quality of life, saw reduced systolic pressure and BNP.

 

Conclusion

MitraClip implantation with DS is as safe and effective as with general anesthesia.

 

Commentary

Simplifying endovascular procedures with no quality compromise has always been beneficial.

 

Performing MitraClip procedures without general anesthesia reduced intensive care days, but with no difference in overall hospital stay. This might be because the researchers looked at patients between 2011 and 2015. After gaining experience and improving devices, this factor might improve as well. 

 

To know the kind of patients that will benefit from this strategy calls for further research.

 

Courtesy of Dr. Carlos Fava.

 

Original Title: Deep Sedation Vs. Geneal Anesthesia in 232 patients undergoing Percutaneous Mitral Valve repair using the MitraClip® System.

Reference: Patrick Horn, et al Catheterization Cardiovascular Intervention 2017 Published online.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

VECTOR: First Percutaneous Aorto-Coronary Bypass Case, a New Conceptual Approach

Coronary obstruction represents one of the most severe complications associated with transcatheter aortic valve implantation, particularly in valve-in-valve scenarios involving surgical bioprostheses, narrow aortic...

Is it safe to use negative chronotropic drugs early after TAVI?

TAVI is associated with a relevant incidence of conduction system disturbances and the development of atrioventricular block that may require permanent pacemaker implantation. Many...

Transapical TMVR in High Risk Patients: Intrepid 5-Year Outcomes

Moderate to severe mitral valve regurgitation (MR) continues is still a high prevalence condition with bad prognosis, particularly among the elderly with left ventricular...

Impact of Balloon Post-Dilation on the Long-Term Durability of Bioprostheses after TAVR

Balloon post-dilation (BPD) during transcatheter aortic valve replacement (TAVR) allows for the optimization of prosthesis expansion and the reduction of residual paravalvular aortic regurgitation....

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Hybrid Coronary Revascularization versus Conventional Bypass Surgery in Left Main Coronary Artery Disease

Significant left main coronary artery (LMCA) disease continues to represent a therapeutic challenge, particularly in patients with complex multivessel disease and high SYNTAX scores,...

VECTOR: First Percutaneous Aorto-Coronary Bypass Case, a New Conceptual Approach

Coronary obstruction represents one of the most severe complications associated with transcatheter aortic valve implantation, particularly in valve-in-valve scenarios involving surgical bioprostheses, narrow aortic...

Comparison of strategies: NMA of IVUS, OCT, or angiography in complex lesions

Percutaneous coronary intervention (PCI) in complex lesions continues to represent a technical challenge in contemporary interventional cardiology. Angiography, although it remains the most widely...