IBERIAN: appendage occlusion registry

The aim of this study was to observe the rate of thromboembolic and hemorrhagic events in a period of 2 years in 167 patients undergoing appendage occlusion with Amplatzer device. 

Appendage occlusion in patients with contraindication to anticoagulation is a safe technique associated with less embolic and bleeding events than expected according to the risk scores. Bleeding incidence of post occlusion was also reduced and more evident in the second year of follow-up. 

J.R. Lopez-Minguez
2014-05-22

Title: The IBERIAN registry: 2-year clinical outcome after left atrial appendage closure with the Amplatzer cardiac plug device in patients with non-valvular atrial fibrillation and contraindications for anticoagulation therapy

More articles by this author

COMPARE II: biolimus eluting stent with biodegradable polymer versus everolimus at 3 years.

This study randomized 2:1 - 2707 patients to biolimus eluting stent with biodegradable polymer versus everolimus eluting stent with permanent polymer. At one year,...

Bivalirudin superior than heparin beyond the use or not of Glycoprotein inhibitors

Bivalirudin benefits in bleeding events versus heparin plus glycoprotein IIbIIIa inhibitors is clear even though  this benefit has not been fully studied at the...

Meta-analysis confirms the reduction in ischemic events with 2nd generation DES versus BMS

This paper included 5 studies that randomized patients to conventional stent versus chromium cobalt everolimus eluting stent; at 2 years, a significantly lower risk...

PARIS register: Non-adherence impact to antiplatelet therapy among men and women

The PARIS registry was a prospective observational study in 5018 patients undergoing coronary angioplasty with stent implantation in 15 centers. Three categories were prespecified...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

COILSEAL: Use of Coils in Percutaneous Coronary Intervention, Useful for Complication Management?

The use of coils as vascular closing tool has been steadily expanding beyond its traditional role in neuroradiology into coronary territory, where it remains...

Treatment of In-Stent Restenosis in Small Vessels with Paclitaxel-Coated Balloons

Coronary artery disease (CAD) in smaller epicardial vessels occurs in 30% to 67% of patients undergoing percutaneous coronary intervention and poses particular technical challenges....

Contemporary Challenges in Left Atrial Appendage Closure: Updated Approach to Device Embolization

Even though percutaneous left atrial appendage (LAA) closure is generally safe, device embolization – with 0 to 1.5% global incidence – is still a...