IN-PACT CORO: OCT validation of drug-eluting balloons

Drug-eluting balloons could reduce intimal hyperplasia detected by OCT in intmerventions with conventional stents. 30 patients were randomized into 3 groups: 10 patients received conventional stents, 10 patients received a drug-eluting balloon prior to the conventional stent, and 10 patients receive a drug-eluting balloon after the conventional stent. We performed angiographic and OCT follow-up at 6 months. There were no angiographic differences after 6 months or clinical differences (death, myocardial infarction, revascularization) after 12 months. The OCT found a lower hyperplasia in patients receiving the drug-eluting balloon, but there were no differences between its use before or after stenting.

Conclusion: In simple de novo coronary lesions treated with BMS, the drug-eluting balloon significantly reduces intimal hyperplasia after 6 months as assessed by OCT The use of the drug-eluting balloon before or after stent implantation had similar efficacy.

francesco_burzotta_europcr
Francesco Burzotta
2013-05-23

Original title: IN-PACT CORO Trial: INtimalhyPerplasiaevAluated by OCT in de novo COROnary lesions treated by drug-eluting balloon and BMS – Final results. 

 

More articles by this author

Coronary obstruction registry after TAVI

There is little information in the literature about the obstruction of the coronary ostia after percutaneous aortic valve implantation. 81 TAVI sites and programs...

Clinical results of TAVI in Asia

Since all the studies available in the literature were conducted in North America or Europe, the results of percutaneous aortic valve replacement in Asia...

RIPCORD study: FFR changes clinical consideration of chest pain

The objective of this study was to evaluate whether routine use of FFR in all the coronary arteries could change the strategy in stable...

Coherex Wave Crest: New device for atrial appendage closure

Appendage closure devices have emerged as an alternative to anticoagulation in fibrillated patients with a contraindication for it. The study included 63 patients with...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

TricValve Transcatheter Bicaval Valve System for Severe Tricuspid Insufficiency: Events at One Year

TricValve is the first bicaval valve system to obtain CE-Mark approval. This device heterotopic device eliminates tricuspid insufficiency reflux into the venous system, reducing...

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...