Meta-analysis confirms the reduction in ischemic events with 2nd generation DES versus BMS

This paper included 5 studies that randomized patients to conventional stent versus chromium cobalt everolimus eluting stent; at 2 years, a significantly lower risk of cardiac death (2.7% for the everolimus eluting stent versus 4% for conventional stent, p = 0013) was observed. Myocardial infarction was reduced by over 80% with drug-eluting stent (0.08% versus 0.8%, P = 0.003). Regarding definite thrombosis differences favoring the drug eluting stent with 0.6% versus 1.4% (p = 0.005) were also observed. 

Conclusion 

The analysis of 5 randomized studies with a total of 4896 patients showed a consistent reduction in fatal and nonfatal ischemic events. 

10_marco_valgimigli
Marco Valgimigli
2014-05-22

Title: Effects of cobalt-chromium everolimus-eluting or bare-metal stent on fatal and non-fatal cardiovascular events: a collaborative patient-level meta-analysis, including 4,896 individuals with a median 2-year follow-up duration

More articles by this author

IBERIAN: appendage occlusion registry

The aim of this study was to observe the rate of thromboembolic and hemorrhagic events in a period of 2 years in 167 patients...

COMPARE II: biolimus eluting stent with biodegradable polymer versus everolimus at 3 years.

This study randomized 2:1 - 2707 patients to biolimus eluting stent with biodegradable polymer versus everolimus eluting stent with permanent polymer. At one year,...

Bivalirudin superior than heparin beyond the use or not of Glycoprotein inhibitors

Bivalirudin benefits in bleeding events versus heparin plus glycoprotein IIbIIIa inhibitors is clear even though  this benefit has not been fully studied at the...

PARIS register: Non-adherence impact to antiplatelet therapy among men and women

The PARIS registry was a prospective observational study in 5018 patients undergoing coronary angioplasty with stent implantation in 15 centers. Three categories were prespecified...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...