PROMUS PREMIER: new everolimus-eluting stent

The study aims to evaluate clinical, angiographic and IVUS results of the new platinum chromium everolimus stent. The new design of the device has additional proximal connectors to enhance the longitudinal strength where distortion is more common. Included were 100 patients with de novo coronary lesions and a reference diameter of 2.5 to 4 mm and a length of

Conclusion: Technical success was high with clinical, angiographic and IVUS showing safety and efficacy without observing any stent deformation.

john_ormistron_europcr
John Ormistron.
2013-05-22

Original title: Clinical, angiographic and IVUS outcomes of the NG PROMUS clinical trial evaluating the novel Promus PREMIER stent. 

More articles by this author

REPRISE II: results obtained with the new valve according to VARC criteria

The objective was to evaluate the safety and efficacy of the Lotus Valve System to treat patients with severe aortic stenosis and high surgical...

DEFLECT I: cerebral protection device in TAVI

Strokes after TAVI occur in between 3.8 and 6.7% of the cases, with new MRI lesions being almost the rule. The TriGuard EDD device...

DISCOVER: new low profile valve with little post-implant regurgitation

The objective of the study was to assess events after 30 days with the DirectFLOW Medical Valve device in patients with severe aortic stenosis...

JUPITER: transapical TAVI device

We evaluated 88 consecutive patients (at this phase) with severe aortic stenosis who received the second-generation device for transapical access. Survival at thirty days...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

CRT 2026 | NAVITOR IDE: Hemodynamic Outcomes and 5-Year Durability of an Intra-Annular Self-Expanding Transcatheter Aortic Valve

As TAVI expands into younger populations and patients with lower surgical risk, prosthesis durability has become a key aspect of long-term management. The NAVITOR...

CRT 2026 | CUT-DRESS Trial: Lesion Preparation with Cutting Balloon

In-stent restenosis (ISR) continues to represent a relevant clinical challenge in contemporary coronary angioplasty practice. Despite advances in drug-eluting stents, neointimal hyperplasia and suboptimal...