TOTAL OCT: Thrombotic load of culprit lesion using OCT. TOTAL substudy.

The thrombotic load of culprit lesion is unidentified in the context of acute myocardial infarction that vindicates the use of thromboaspiration. This work is a substudy of TOTAL in patients underwent OCT before stenting. 214 patients randomized to thromboaspiration or only angioplasty were included.

No differences between groups in plaque load, thrombus absolute volume, or number of quadrants with thrombi were observed. Both groups presented a low thrombus load in the lesion after surgery.

Conclusion

Thrombus load before and after angioplasty was similar among those patients who underwent thromboaspiration and those who not.

9_t_sheth
T. Sheth
2015-05-20

Original title: Culprit lesion thrombus burden after manual aspiration thrombectomy or PCI alone in STEMI: The OCT Substudy of the TOTAL (ThrOmbecTomy versus PCI Alone) Trial.

More articles by this author

NONSTEMI: Superiority of early angioplasty in non-ST elevation myocardial infarction

The European guidelines recommend revascularization within 24 hours in high-risk patients with No ST segment elevation myocardial infarction. It is unclear whether these patients...

TOTAL stroke: increased risk of stroke with thromboaspiration

There are many doubts about the benefit of manual thromboaspiration, not only in terms of improvement of the clinical end point but also the...

PARTNER II: Less oversizing to reduce paravalvular failure with the new generation of SAPIEN 3

The new generation SAPIEN 3 valve was designed to reduce paravalvular aortic regurgitation. The objective of this work was to evaluate the influence of...

IN.PACT Global Study: Pharmacological balloon in long lesions of the Superficial Femoral Artery (SFA)

Long lesions (≥ 15 cm), total occlusions, and in-stent restenosis represent a unique treatment challenge in peripheral vascular disease. IN.PACT Global study is a...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

TricValve Transcatheter Bicaval Valve System for Severe Tricuspid Insufficiency: Events at One Year

TricValve is the first bicaval valve system to obtain CE-Mark approval. This device heterotopic device eliminates tricuspid insufficiency reflux into the venous system, reducing...

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...