Similar results of drug-eluting stents with biodegradable polymer versus permanent

Original title: Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting StentA Randomized, Controlled, Noninferiority Trial.NEXT trial. Reference: Masahiro Natsuaki et al. J Am CollCardiol 2013;62:181–90.

Drug-eluting stents with biodegradable polymer were designed to counteract the long-term adverse effects on the vascular wall of permanent polymer. 

This prospective, multicenter, randomized, non-inferiority design study, compared the biolimus eluting stent with biodegradable polymer NOBORI (Terumo, Tokyo, Japan) versus everolimus-eluting stent with permanent biocompatible polymer XIENCE/PROMUS. The primary efficacy end point was the revascularization of the target lesion after a year and the safety end point, a composite of death and myocardial infarction at 3 years. A total of 3235 patients were included (1617 received NOBORI stent and 1618 XIENCE/PROMUS). A clinical follow-up was made to the entire population, angiographic follow-up of 2103 patients (65 %). The revascularization lesion in the first year (primary endpoint) occurred in 67 patients (4.2 %) in the NOBORI group versus 66 patients (4.2 %) of the XIENCE/ PROMUS group, (p = 0.93, for non-inferiority < 0.0001). The incidence of definite stent thrombosis at one year was low and similar between the two stents (0.25 % versus 0.06 %, p= .18). Late lumen loss in patients who underwent angiographic follow-up was also similar between the two stents (0.03 ± 0.39 mm versus 0.06 ± 0.45, p = 0.52). The only significant difference was the higher incidence of fracture of the stent in the patients who received NOBORI (3.1 % versus 0 % p = 0.004). 

Conclusion: 

The clinical and angiographic results of the biolimus eluting stent with biodegradable polymer were not inferior to everolimus-eluting stent with permanent polymer. Both stents showed a low revascularization incidence and extremely low thrombosis. 

Editorial Comment

Theoretical advantage of degradable polymer to reduce chronic inflammation of the vessel wall and therefore reduce its potential consequences such as restenosis or thrombosis, probably take place in a long term. Furthermore biolimus eluting stent showed a significantly higher incidence of stent fracture whose potential consequences were not reflected a year but should be monitored also in the longer term. 

SOLACI.ORG

More articles by this author

Pretreatment with DAPT in Acute Coronary Syndrome: An Ongoing Debate?

In acute coronary syndrome (ACS) dual antiplatelet therapy (DAPT) has become a fundamental pillar after percutaneous coronary intervention (PCI), preventing stent thrombosis and acute...

Another Blow for Intra-Aortic Balloon Pumo Counterpulsation? Randomized Study on Its Use in Chronic Heart Failure Progressing to Cardiogenic Shock

Cardiogenic shock (CS) remains a condition with extremely high mortality (around 50%). While most therapies for this pathology have been studied in CS secondary...

Radial Patency in Coronary Procedures: Is Heparin Enough or Should We Aim for Distal Transradial Access?

Transradial access is the preferred route in most coronary procedures due to its proven reduction in mortality compared to transfemoral access. However, one of...

iFR- vs. FFR-Guided Coronary Revascularization: 5-Year Clinical Outcomes

The assessment of coronary stenosis using coronary physiology has become a key tool in guiding revascularization. The two most widely used techniques are fractional...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Pretreatment with DAPT in Acute Coronary Syndrome: An Ongoing Debate?

In acute coronary syndrome (ACS) dual antiplatelet therapy (DAPT) has become a fundamental pillar after percutaneous coronary intervention (PCI), preventing stent thrombosis and acute...

Measuring Post-TAVI Gradients and Their Implications: Are Invasive and Echocardiographic Assessments Comparable?

Transcatheter aortic valve implantation (TAVI) is considered the treatment of choice for a significant proportion of patients with symptomatic aortic stenosis. Outcomes have improved...

Another Blow for Intra-Aortic Balloon Pumo Counterpulsation? Randomized Study on Its Use in Chronic Heart Failure Progressing to Cardiogenic Shock

Cardiogenic shock (CS) remains a condition with extremely high mortality (around 50%). While most therapies for this pathology have been studied in CS secondary...