OBSERVANT II: Post TAVR 30-Day and 6-Month Stroke Predictors

Despite stroke rate has declined since the early days of transcatheter aortic valve replacement (TAVR), it remains significant, reaching 1% to 3% 30 days after procedure. Since TAVR has seen a progressive expansion to the low risk and young populations, identifying risk factors in patient selection and management is crucial for us to prevent stroke. 

Estudio OBSERVANT II: Predictores de accidente cerebrovascular a 30 días y a 6 meses después del TAVI

Even though predictors of 30-day stroke have been described, such as the interaction between a calcified native valve and the device, hemodynamic instability and other patient-related factors are not taken into account as mid and long term predictors. 

The aim of this analysis within the OBSERVANT II framework ─ a multicenter, observational and prospective study ─ was to look into 30-day and 6-month stroke incidence after TAVR, and to identify both procedure and patient related predictors. 

Primary end point revolved around stroke and TAVR incidence at 30 days and 6 months. 

This analysis included 2753 patients, mean age 81, mostly women. 61% presented EUROSCORE II over 4%. The transfemoral approach was used in most cases, and the most frequent device was EVOLUT R/PRO (53%), followed by SAPIEN 3 (27%), ACURATE Neo (10%) and PORTICO (8%). There were no significant differences between devices as regards stroke incidence. 

Stroke incidence at 30 days resulted 1.3%, and 2.4% at 6 months. As regards predictors, logistic regression analysis revealed predilation (OR: 2.28, 95% CI: 1.12–4.65, p = 0.023), diabetes (OR: 3.10, 95% CI: 1.56–6.18, p = 0.001) and <50% ejection fraction (OR: 2.15, 95% CI: 1.04–4.47, p = 0.04) were independent predictors of 30-day stroke. The use of dual antiplatelet therapy (DAPT) and oral anticoagulation was inversely associated to stroke risk. 

Read also: Ultrathin Stents Shown Safe and Effective in Real World Patients.

At 6 months, diabetes (HR: 2.07, 95% CI: 1.25–3.42, p = 0.004), neurological dysfunction (HR: 3.92, 95% CI: 1.52–10, p = 0.004) and critical status (HR: 3.05, 95% CI: 1.21–7.72, p = 0.018) resulted independent predictors. Bicuspid valve also resulted a significant predictor of 6-month stroke, but with ample confidence interval (HR: 4.75, 95% CI: 1.44–15.7 p = 0.011). Also, the use of simple/dual antiplatelet treatment and anticoagulation was inversely associated to stroke at 6 months. 

Conclusion

To conclude, stroke rate after TAVR is generally low and has seen a decline since the early days of this strategy. This study reveals that most predictors of stroke at 30 days and 6 months after TAVR are patient related. This might contribute to improve risk stratification of patients before procedure. 

Dr. Andrés Rodríguez

Dr. Andrés Rodríguez.
Member of the Editorial Board of SOLACI.org.

Original Title: Incidence and predictors of 30‐day and 6‐month stroke after TAVR: Insights from the multicenter OBSERVANT II study.

Reference: Riccardo Gorla MD, PhD et al Catheter Cardiovasc Interv. 2023;1–10.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

VECTOR: First Percutaneous Aorto-Coronary Bypass Case, a New Conceptual Approach

Coronary obstruction represents one of the most severe complications associated with transcatheter aortic valve implantation, particularly in valve-in-valve scenarios involving surgical bioprostheses, narrow aortic...

Is it safe to use negative chronotropic drugs early after TAVI?

TAVI is associated with a relevant incidence of conduction system disturbances and the development of atrioventricular block that may require permanent pacemaker implantation. Many...

Transapical TMVR in High Risk Patients: Intrepid 5-Year Outcomes

Moderate to severe mitral valve regurgitation (MR) continues is still a high prevalence condition with bad prognosis, particularly among the elderly with left ventricular...

Impact of Balloon Post-Dilation on the Long-Term Durability of Bioprostheses after TAVR

Balloon post-dilation (BPD) during transcatheter aortic valve replacement (TAVR) allows for the optimization of prosthesis expansion and the reduction of residual paravalvular aortic regurgitation....

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

VECTOR: First Percutaneous Aorto-Coronary Bypass Case, a New Conceptual Approach

Coronary obstruction represents one of the most severe complications associated with transcatheter aortic valve implantation, particularly in valve-in-valve scenarios involving surgical bioprostheses, narrow aortic...

Comparison of strategies: NMA of IVUS, OCT, or angiography in complex lesions

Percutaneous coronary intervention (PCI) in complex lesions continues to represent a technical challenge in contemporary interventional cardiology. Angiography, although it remains the most widely...

Is upper-limb aerobic training an effective alternative to lower-limb exercise in peripheral artery disease?

Peripheral artery disease is associated with impaired functional capacity, reduced walking distance, and poorer quality of life, and structured exercise is a class I...