The radial access is a viable alternative in infarction complicated with cardiogenic shock

Original title: Arterial access site utilization in cardiogenic shock in the United Kingdom: Is radial access feasible? Reference: Mamas A. Mamas, et al. Am Heart J 2014;167:900-08

Cardiogenic shock in the context of acute myocardial infarction is associated with high mortality, and represents approximately 10% of major bleeding complications. Radial Access reduces mortality mainly by reducing bleeding; however, AMI patients complicated with CS undergoing PCI via radial access have only been assessed in small studies. 

This study analyzed 7231 PCI patients hospitalized with AMI complicated with CS, in UK. 1877 (35%) received radial access and 5354 (64%) femoral access.

Baseline characteristics were similar, although those approached by femoral access site were mostly women, diabetic, requiring higher inotropic support or intraaortic balloon counterpulsation and mechanical ventilation.

Global mortality at 30 days was 36.3% for the whole cohort, 24.7% for the radial access group vs. 39.8% for the femoral access group (p<0.01). This difference was also maintained at 12 months.

After propensity score matching was applied to eliminate possible confusing factors, 1402 patients remained in each group for final analysis, and significant lower mortality was observed in the radial Access group at 30 days (22.8% vs 29.9% p<0.001).

Major bleeding rate was also lower in the radial access group. (1.5% vs 3.5%; p<0.0001). The radial access site resulted an independent predictor of lower event rates at 30 days and this benefit was observed at a time when more than 50% of cases at this center were performed via radial approach. 

Conclusion

Even though most of PCI procedure in CS patients in UK are performed via femoral approach, the radial approach has become a feasible alternative for this high risk population in experienced centers.

Editorial Comment

The safety and efficacy of the radial access site had been shown in other scenarios but it had not been correctly assessed for this group of patients. This study has shown the radial access site is safe and can reduce mayor bleeding and mortality also in the difficult scenario of cardiogenic shock. Nevertheless, it demands highly trained, expert operators. 

Courtesy of Dr. Carlos Fava
Interventional Cardiologist
Favaloro Foundation – Buenos Aires

Dr. Carlos Fava para SOLACI.ORG

More articles by this author

AHA 2024 | SUMMIT

It has been previously shown that the pharmacological treatment of obesity (semaglutide) can reduce cardiovascular events in patients with cardiac failure (CF) and preserved...

AHA 2024 – BPROAD

Hypertension (elevated blood pressure, BP) is the most common comorbidity among diabetic patients and has been associated with higher cardiovascular risk, though as a...

Coronary Artery Disease in Aortic Stenosis: CABG + SAVR vs. TAVR + PCI: Data from Spanish Centers

Multiple randomized studies have shown comparable or superior efficacy of transcatheter aortic valve replacement (TAVR) vs. coronary artery bypass graft (CABG).  However, many of...

Evolution of Small Balloon-Expandable Valves

Small aortic rings (20 mm) have posed a significant challenge for both surgery and transcatheter aortic valve implantation (TAVI) due to their association with an...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...