ADVANCE II: Low incidence of permanent pacemaker for self -expandable valve

The incidence of permanent pacemaker implantation (PPM) is variable between the different series within 30 days of the aortic valve implantation with the CoreValve prosthesis. The aim of this study was to investigate the conduction abnormalities and PPM according to the Conduction Disorders Guide. This multicentre prospective study with a follow-up to 7 days, 30 days and 6 months observed a rate of implant PPM of 13.3% when the valve CoreValve was implanted according to the recommended technique. 42% of the left branch blocks and first grade level atrial-ventricular blocks resolved spontaneously within 30 days. The new conduction disorders and the need for PPM (class I and II) to 30 days were significantly associated with lower prosthesis implants.

Conclusion

The study showed that CoreValve implantation made

More articles by this author

SOURCE XT: Results at 2 years of SAPIEN XT valve

Multicenter prospective study included 2688 patients with a mean age of 81.4 years and 20.5 EuroScore. The all-cause mortality at 2 years was 27.7%...

NOBORI II: Final 5-year results of drug-eluting stent with bio-absorbable polymer

This study evaluated the performance of Nobori biolimus bio-absorbable polymer stent in real-world patients. A total of 3067 consecutive patients followed up to 5...

TRYTON dedicated bifurcation stent in left main coronary artery

TRYTON is a cobalt chromium device specifically dedicated for bifurcation lesions to be implanted in the side branch. Circumflex artery is the major lateral...

UK TAVI Registry: Long-term results of TAVI in the UK

This record has been created in order to evaluate the results of percutaneous aortic valve replacement in the UK and currently includes more than...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...