EVOLUTION: Comparative study of non-inferiority of two sirolimus eluting stents: One with permanent polymer and the other with degradable polymer.

The EVOLUTION study, (Dr. Junbo Ge, Shanghai Institute, China), compared two sirolimus-eluting stents, one with permanent polymer (Cypher Select, Cordis Corporation, Miami Lakes, Florida, USA) and another with degradable polymer (Excel, JW Medical System Ltd, Weihai, China). A randomized (2:1) was used, open and non-inferiority, including 1923 patients in 30 centers in China (December 2008 to September 2010). The study excluded injured patients with unprotected trunk, rotablator use or previous angioplasty (

The researchers concluded that, until annual follow-up, sirolimus-eluting stent with biodegradable polymer is comparable to sirolimus-eluting stent with permanent polymer. A longer follow-up will be needed to clarify its long-term security.

Ge-EVOLUTION
Junbo Ge
2012-05-17

More articles by this author

CIBELES: Xience V comparative study vs Cypher for the treatment of total chronic occlusions.

Spanish-Portuguese multicentre CIBELES study (Raul Moreno, Madrid, Spain) compared two drug-eluting stents - an everolimus (Xience V, Abbott Vascular, USA) and a sirolimus-releasing eluting...

SORT OUT V: Comparison of drug-eluting stents: One with degradable polymer releasing biolimus and the other a permanent polymer sirolimus stent.

SORT OUT V randomized trial (Odense University Hospital, Denmark) compared Nobori stent, a drug-eluting stent with biodegradable polymer eluting biolimus, versus CYPHER a drug-eluting...

ROMA II RELOAD: Additional charge of statin (rosuvastatin 40 mg or atorvastatin 80 mg within 24 hours of procedure) in patients on whom elective...

ROMA II RELOAD multicenter study (General Hospital Umberto I, University of Rome, Rome, Italy) assessed the impact of an additional charge of statin in...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...