EVOLUTION: Comparative study of non-inferiority of two sirolimus eluting stents: One with permanent polymer and the other with degradable polymer.

The EVOLUTION study, (Dr. Junbo Ge, Shanghai Institute, China), compared two sirolimus-eluting stents, one with permanent polymer (Cypher Select, Cordis Corporation, Miami Lakes, Florida, USA) and another with degradable polymer (Excel, JW Medical System Ltd, Weihai, China). A randomized (2:1) was used, open and non-inferiority, including 1923 patients in 30 centers in China (December 2008 to September 2010). The study excluded injured patients with unprotected trunk, rotablator use or previous angioplasty (

The researchers concluded that, until annual follow-up, sirolimus-eluting stent with biodegradable polymer is comparable to sirolimus-eluting stent with permanent polymer. A longer follow-up will be needed to clarify its long-term security.

Ge-EVOLUTION
Junbo Ge
2012-05-17

More articles by this author

CIBELES: Xience V comparative study vs Cypher for the treatment of total chronic occlusions.

Spanish-Portuguese multicentre CIBELES study (Raul Moreno, Madrid, Spain) compared two drug-eluting stents - an everolimus (Xience V, Abbott Vascular, USA) and a sirolimus-releasing eluting...

SORT OUT V: Comparison of drug-eluting stents: One with degradable polymer releasing biolimus and the other a permanent polymer sirolimus stent.

SORT OUT V randomized trial (Odense University Hospital, Denmark) compared Nobori stent, a drug-eluting stent with biodegradable polymer eluting biolimus, versus CYPHER a drug-eluting...

ROMA II RELOAD: Additional charge of statin (rosuvastatin 40 mg or atorvastatin 80 mg within 24 hours of procedure) in patients on whom elective...

ROMA II RELOAD multicenter study (General Hospital Umberto I, University of Rome, Rome, Italy) assessed the impact of an additional charge of statin in...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

CRT 2026 | NAVITOR IDE: Hemodynamic Outcomes and 5-Year Durability of an Intra-Annular Self-Expanding Transcatheter Aortic Valve

As TAVI expands into younger populations and patients with lower surgical risk, prosthesis durability has become a key aspect of long-term management. The NAVITOR...

CRT 2026 | CUT-DRESS Trial: Lesion Preparation with Cutting Balloon

In-stent restenosis (ISR) continues to represent a relevant clinical challenge in contemporary coronary angioplasty practice. Despite advances in drug-eluting stents, neointimal hyperplasia and suboptimal...