Melody

The ducts of the right ventricle to the pulmonary artery are used in approximately 20 % of all patients with congenital defects including tetralogy of Fallot with pulmonary atresia, truncus arteriosus, transposition of great arteries with VSD, pulmonary stenosis, etc.The Melody trans catheter pulmonary valve is composed of three leaflets of bovine jugular vein mounted on a platinum iridium balloon expandable stent.This study included 120 patients to evaluate the performance of the valve to 6 months after implantation (gradient ≤ 30 mmHg, failure

Conclusion

The study confirms the excellent performance of the Melody pulmonary valve in a real-world population.

10_aimee_armstrong
Aimee K. Armstrong
2014-03-31

Original title: One Year Follow-up of the Melody Transcatheter Pulmonary Valve Multicenter Post Approval Study.

More articles by this author

CORP-2 Trial: Colchicine effective in reducing the recurrence of pericarditis associated withconventional anti-inflammatory pattern.

Colchicine is effective in treating an acute pericarditis event and initial recurrences;however, there is no conclusive data on its efficacy and safety in the...

Negative ultrasensitive troponin T values may help discriminate patients with chest pain in the emergency

New laboratory tests can detect minimally elevated  levels few hours before regarding detection methodologies of previous generations.The hypothesis of this study is that patients...

LAPLACE 2: Evolocumab effective in reducing LDL associated with statins

There are several patients who do not reach recommended LDL cholesterol despite maximally tolerated doses of statins levels.The Evolocumab is a monoclonal antibody that...

MADIT -CRT: Increased survival with resynchronization therapy plus defibrillator in patients with mild heart failure.

The MADIT -CRT study (Multicenter Automatic Defibrillator Implantation with Cardiac Resynchronization Therapy) had shown that early intervention with cardiac resynchronization therapy plus defibrillator in...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...