Melody

The ducts of the right ventricle to the pulmonary artery are used in approximately 20 % of all patients with congenital defects including tetralogy of Fallot with pulmonary atresia, truncus arteriosus, transposition of great arteries with VSD, pulmonary stenosis, etc.The Melody trans catheter pulmonary valve is composed of three leaflets of bovine jugular vein mounted on a platinum iridium balloon expandable stent.This study included 120 patients to evaluate the performance of the valve to 6 months after implantation (gradient ≤ 30 mmHg, failure

Conclusion

The study confirms the excellent performance of the Melody pulmonary valve in a real-world population.


Aimee K. Armstrong
2014-03-31

Original title: One Year Follow-up of the Melody Transcatheter Pulmonary Valve Multicenter Post Approval Study.

More articles by this author

CORP-2 Trial: Colchicine effective in reducing the recurrence of pericarditis associated withconventional anti-inflammatory pattern.

Colchicine is effective in treating an acute pericarditis event and initial recurrences;however, there is no conclusive data on its efficacy and safety in the...

Negative ultrasensitive troponin T values may help discriminate patients with chest pain in the emergency

New laboratory tests can detect minimally elevated  levels few hours before regarding detection methodologies of previous generations.The hypothesis of this study is that patients...

LAPLACE 2: Evolocumab effective in reducing LDL associated with statins

There are several patients who do not reach recommended LDL cholesterol despite maximally tolerated doses of statins levels.The Evolocumab is a monoclonal antibody that...

MADIT -CRT: Increased survival with resynchronization therapy plus defibrillator in patients with mild heart failure.

The MADIT -CRT study (Multicenter Automatic Defibrillator Implantation with Cardiac Resynchronization Therapy) had shown that early intervention with cardiac resynchronization therapy plus defibrillator in...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

Redo-TAVI with SAPIEN 3: 30-Day Outcomes

The indications for transcatheter aortic valve implantation (TAVI) have rapidly expanded to include intermediate- and low-risk patients, extending its use to younger individuals with...

DAPT ≤30 Days After Drug-Coated Balloon Coronary Angioplasty

Drug-coated balloon (DCB) coronary angioplasty without stent implantation has become a well-established alternative in several clinical scenarios, particularly in patients at high bleeding risk...

Coronary artery disease progression after transcatheter aortic valve replacement: quantitative coronary angiography and Quantitative Flow Ratio analysis

The coexistence of coronary artery disease and severe aortic stenosis is common among patients undergoing transcatheter aortic valve replacement (TAVR). However, the impact of...