SECURITY: 6 months versus 12 months of dual anti-aggregation using 2nd generation DES

This multicenter noninferiority design work included 1399 patients randomized to receive 6 months (n = 682) versus 1 year (n = 717) dual anti-aggregation after implantation of 2nd generation drug-eluting stent. The primary end point was a composite of cardiac death, myocardial infarction, stroke, definite or probable thrombosis, and major bleeding. At 12 months follow-up the primary end point rate was 4.5% in those who received 6 months versus 3.7% in those who received 12 months (p = 0.469). The incidence of definite or probable thrombosis when considering separately, there were no differences (0.3% versus 0.4%, P = 0.694). 

Conclusion 

Treatment with 6 months of dual anti-aggregation was not minor than 12 months in patients who received angioplasty with 2nd generation drug-eluting stents. 

3_antonio_colombo
Antonio Colombo
2014-09-16

Original title: A Prospective, Randomized Trial of Six Months Versus 12 Months of Dual Antiplatelet Therapy Following Coronary Drug-Eluting Stent Implantation.

 

More articles by this author

OPTIMIZE: 3 months versus 12 months of dual anti-aggregation with zotarolimus-eluting stents

The current recommendation for dual anti-aggregation post-DES implantation is 12 months. However, the ideal length for specific types of stents is unclear. This study...

VELOCITY: Peritoneal hypothermia in patients undergoing primary angioplasty

There are clinics hypothesis that systemic hypothermia (≤34.9) could reduce infarct size if set before reperfusion. Peritoneal lavage had a well-established safety profile and...

TRANSLATE-ACS: One-year prasugrel versus clopidogrel after acute coronary syndrome

Platelet inhibition is critical in reducing atherothrombotic risk in the short and long term after an acute coronary syndrome, especially if the patient has...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...