SMART: Manual Thrombectomy vs. Rheolytic Aspiration in ST-segment Elevation Acute Myocardial Infarction.

Dr. David Antoniucci presented the immediate results of randomized trial SMART SMART (n=80, 1:1) comparing manual thrombectomy (MAT) vs. rheolytic aspiration (RT) in the context of ST elevation acute myocardial infarction (≤6 hours). In this study, primary outcome was residual thrombus burden after aspiration assessed with optical coherence tomography (OCT). Thrombus burden was defined as the number of quadrants of the coronary vessel containing residual thrombus.

Conclusion: with better myocardial reperfusion, mechanical aspiration was not superior to manual aspiration for thrombus burden reduction assessed by OCT.

Antoniucci_x_smart_pci_paris_2012
David Antoniucci
2012-05-16

More articles by this author

DISCOVER FLOW: Correlation of conventional FFR vs non invasive FFR obtained with MSCT for successful stenting.

The DISCOVER FLOW trial has recently showed an excellent correlation between fractional flow reserve values (FFR) traditionally obtained with coronary CT angiography (CCTA) and...

CLI-OPCI: Optical coherence tomography (OCT)-guided stent implantation vs. conventional angiography guided angioplasty.

CLI-randomized study CLI-OPCI (n = 670, 1:1) evaluated the impact of stent implantation guided by angiography and optical coherence tomography (OCT), versus angioplasty guided...

TROFI: Minimal intra-stent flow area in STEMI patients post primary PCI with or without manual thrombus aspiration.

Professor Serruys presented the results of the TROFI trial that compares the minimal intra-stent flow area in STEMI patients post primary PCI with or...

DESolve I FIM: Evaluation of a FIM trial results of a bioabsorbable stent (15 patients).

 This trial is a prospective evaluation of DESolveTM bioabsorbable coronary stent implantation in a 15 patient cohort enrolled in New Zealand and Belgium. At...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

TricValve Transcatheter Bicaval Valve System for Severe Tricuspid Insufficiency: Events at One Year

TricValve is the first bicaval valve system to obtain CE-Mark approval. This device heterotopic device eliminates tricuspid insufficiency reflux into the venous system, reducing...

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...