This record has been created in order to evaluate the results of percutaneous aortic valve replacement in the UK and currently includes more than 4500 patients with 100% follow-up for mortality. The 3-year mortality was 61.6 % beyond the device or path. Atrial fibrillation, renal failure, chronic obstructive pulmonary disease and a EuroSCORE > 18.5 were independent predictors of mortality in the multivariate analysis.

As related to the procedure and type of prosthesis, aortic regurgitation presence or the need for pacemaker did not reach statistical significance for predicting mortality. The 5-year survival was almost 50 %.

Conclusion

The long-term survival after TAVI is determined more by intrinsic patient factors than for process factors.

A. Duncan
2014-05-23

Title: 3- and 5-year outcomes after TAVI in high-risk patients with severe aortic stenosis: the UK TAVI registry

More articles by this author

SOURCE XT: Results at 2 years of SAPIEN XT valve

Multicenter prospective study included 2688 patients with a mean age of 81.4 years and 20.5 EuroScore. The all-cause mortality at 2 years was 27.7%...

NOBORI II: Final 5-year results of drug-eluting stent with bio-absorbable polymer

This study evaluated the performance of Nobori biolimus bio-absorbable polymer stent in real-world patients. A total of 3067 consecutive patients followed up to 5...

TRYTON dedicated bifurcation stent in left main coronary artery

TRYTON is a cobalt chromium device specifically dedicated for bifurcation lesions to be implanted in the side branch. Circumflex artery is the major lateral...

DISCOVER Trial: Results at one year of the new nonmetallic percutaneous aortic valve

Direct Flow Medical prosthesis is a nonmetallic, repositionable, recaptured valve (even after posts dilate), that does not require a pacemakers use during both implantation...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...