Clinical and haemodynamic outcomes with contemporary intra- vs. supra-annular valves: The HERA-TAVI Registry

According to the latest European guidelines, transcatheter aortic valve implantation (TAVI) is the recommended treatment for patients aged ≥70 years with symptomatic severe aortic stenosis, regardless of their estimated surgical risk. As TAVI is increasingly performed in patients with longer life expectancy, the focus has progressively shifted from procedural feasibility to device-specific performance, safety, and long-term clinical implications.

Nueva válvula aórtica balón-expandible: resultados a 30 días en pacientes con anillo aórtico pequeño

Technological advances have led to the development of new-generation self-expanding transcatheter heart valves (THVs), designed to improve implantation ease, annular sealing, and haemodynamic performance. In this setting, intra-annular (IA) and supra-annular (SA) valve designs represent two distinct engineering strategies, each with potential advantages and limitations. Supra-annular configurations have been associated with larger effective orifice areas and lower transvalvular gradients, whereas intra-annular platforms may offer advantages regarding coronary access and lifetime management.

Recent prospective single-arm studies have demonstrated excellent safety and optimal haemodynamic performance for both new-generation intra-annular and supra-annular self-expanding valves (SEVs).

However, comparative evidence between these contemporary platforms remains limited, as most available analyses originate from single-centre or single-country experiences, include mixed device generations, or focus on selected anatomical subgroups and short-term outcomes.

Read also: Redo-TAVI with SAPIEN 3: 30-Day Outcomes.

To address this gap, the HERA-TAVI study (Clinical and HEmodynamic Outcomes with ContempoRary Intra- and Supra-Annular Self-Expanding Valves) was designed to compare the clinical outcomes and haemodynamic performance of new-generation IA and SA SEVs at 30 days and 1 year using a large, contemporary real-world cohort.

A total of 2,607 patients treated between 2021 and 2025 were included. The IA-SEVs evaluated were Navitor/Navitor Vision (Abbott), while the SA-SEVs were Evolut FX/FX+ (Medtronic). Propensity score matching (PSM) was performed, yielding 892 well-balanced matched pairs.

Regarding the primary endpoint at 1 year, there were no significant differences in the composite of all-cause mortality, disabling stroke, or heart failure hospitalization (IA: 12.6% vs. SA: 11.3%; p=0.422).

Read also: Coronary artery disease progression after transcatheter aortic valve replacement: quantitative coronary angiography and Quantitative Flow Ratio analysis.

Although overall efficacy was comparable, the two platforms exhibited distinct safety profiles. IA-SEVs (Navitor) were associated with higher rates of permanent pacemaker implantation (PPI) (22.1% vs. 16.3%; p=0.007) and pericardial tamponade (1.1% vs. 0.2%; p=0.020). Conversely, SA-SEVs (Evolut FX) were associated with a higher incidence of major or life-threatening bleeding (4.2% vs. 2.6%; p<0.001). Device success according to VARC-3 criteria was similarly high in both groups (>90%).

From a haemodynamic standpoint, both platforms maintained low and comparable mean transvalvular gradients at 1 year (7 mmHg in both groups; p=0.429). The incidence of moderate or severe paravalvular leak (PVL) was low and comparable (2.2% in IA vs. 1.6% in SA). The IA platform showed a higher rate of mild PVL at 30 days, although this difference diminished by the 1-year follow-up.

Conclusion: H3: Similar efficacy, different safety profiles

Contemporary intra-annular and supra-annular self-expanding valve platforms demonstrated equivalent clinical outcomes regarding mortality and major adverse events at 1 year. Device selection should therefore be individualized, taking into account patient anatomy, the risk of conduction disturbances, vascular access, and lifetime management strategies, particularly the potential need for future coronary access.

Original Title: Clinical and haemodynamic outcomes with contemporary intra- and supra-annular self-expanding valves: the multicentre international HERA-TAVI registry.

Reference: EuroIntervention. 2026;22:e730-e740.


 

Dr. Andrés Rodríguez
Dr. Andrés Rodríguez
Member of the Editorial Board of solaci.org

More articles by this author

Redo-TAVI with SAPIEN 3: 30-Day Outcomes

The indications for transcatheter aortic valve implantation (TAVI) have rapidly expanded to include intermediate- and low-risk patients, extending its use to younger individuals with...

Coronary artery disease progression after transcatheter aortic valve replacement: quantitative coronary angiography and Quantitative Flow Ratio analysis

The coexistence of coronary artery disease and severe aortic stenosis is common among patients undergoing transcatheter aortic valve replacement (TAVR). However, the impact of...

UNICORN Technique to Prevent Coronary Obstruction During TAVI: Initial Results From a Multicenter Study

Coronary obstruction is an uncommon but potentially catastrophic complication of transcatheter aortic valve implantation (TAVI), particularly in valve-in-valve procedures, TAV-in-TAV interventions, or in patients...

Hemodynamic Outcomes of Edge-to-Edge Repair in Degenerative and Functional Mitral Regurgitation

Transcatheter edge-to-edge mitral valve repair (M-TEER) has become an established therapeutic option for mitral valve disease. Among the available techniques, M-TEER using the MitraClip...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

Redo-TAVI with SAPIEN 3: 30-Day Outcomes

The indications for transcatheter aortic valve implantation (TAVI) have rapidly expanded to include intermediate- and low-risk patients, extending its use to younger individuals with...

DAPT ≤30 Days After Drug-Coated Balloon Coronary Angioplasty

Drug-coated balloon (DCB) coronary angioplasty without stent implantation has become a well-established alternative in several clinical scenarios, particularly in patients at high bleeding risk...

Coronary artery disease progression after transcatheter aortic valve replacement: quantitative coronary angiography and Quantitative Flow Ratio analysis

The coexistence of coronary artery disease and severe aortic stenosis is common among patients undergoing transcatheter aortic valve replacement (TAVR). However, the impact of...