img

EuroPCR 2015.

Find the coverage of the Congress- May 19 - 22 at the Palais des Congrès in Paris, France

The SOLACI@euroPCR Session "Registries and imaging in TAVI and PCI, A Latin American perspective"  was held on Wednesday 20th, at 10:30 in Room 342 AB, under the euroPCR Congress 2015.

// Read the program

If you cannot view the articles, click here

PRAGUE 13 trial
Fundamentos e objetivos: A intervenção coronária percutânea (PCI) primária da artéria culpada pelo infarto agudo do miocárdio com supra de ST (STEMI) ...

RESERVOIR trial demonstra não inferioridade de um stent farmacológico sem polímero em pacientes diabéticos.
Fundamentos e objetivo: Pacientes com diabetes mellitus continuam a ser de alto risco para reestenose e eventos cardiovasculares adversos apesar do uso de stents farmacológicos (DES). Os DES ...

Estudo FFRCT RIPCORD: a FFR derivada da angiotomografia de coronárias pode mudar a estratégia terapêutica?
Fundamentos e objetivos:  A reserva de fluxo fracionada (FFR) Invasiva é uma ferramenta bem validada e reprodutível para a detecção de lesão causadora de ...

Estudo EGO-BIOFREEDOM: follow up sequencial longitudinal por OCT de stent sem polímero liberador de biolimus-A9.
Objetivos: O novo stent Biolimus-A9 (BA9) livre de polímero BioFreedom (Biossensores Europe SA, Morges, Suiça) foi estudado usando follow-ups (FU) sequenciais longitudinais por ...

TAVR é um procedimento tão seguro e eficaz quanto a substituição cirúrgica num seguimento de dois anos em pacientes de menor risco.
Fundamentos e  Objetivos: A substituição da válvula aórtica via transcateter (TAVR) é uma opção em determinados pacientes cirúrgicos de ...

SORT OUT VII
Fundamentos e Objetivo: A persistência do polímero nos DES de primeira e segunda gerações após a liberação completa do fármaco tem sido ...

Avaliação do um novo sistema de liberação de balão coronariano auto-posisionável STENTYS®
Fundamentos: O novo sistema de entrega de balão STENTYS® foi desenvolvido para auto-posicionamento, com stent eluidor de sirolimus (SES). Consiste em inflar um balão com baixas ...

Stent eluidor de sirolimus com polímero absorvível apresenta superioridade em relação a stent eluidor de everolimus com polímero durável
Fundamentos: Ainda há controvérsias em relação à superioridade dos polímeros absorvíveis em relação aos polímeros ...

Estudo MASTER demonstra a segurança e eficácia de polímeros biodegradáveis de stents farmacológicos em relação aos stents convencionais em pacientes com STEMIs
Fundamentos: Diversos estudos para avaliação de segurança e eficácia dos stents farmacológicos com polímeros biodegradáveis estão em ...

Resposta cicatricial vascular a longo prazo de balões eluídos com paclitaxel após stents convencionais é superior em relação à utilização exclusiva de stents convencionais em STEMIs: subanálise de OCT do estudo PEBSI
Fundamentos: Os stents farmacológicos (DES) diminuem as taxas de reestenose, no entanto, ainda existem preocupações sobre a segurança e eficácia da ...

Estudo LIPSIA-CONDITIONING demonstra redução de isquemia com a combinação do condicionamento isquêmico pré e pós procedimento em relação ao grupo controle em pacientes com STEMIs
Fundamentos: A reperfusão rápida da artéria coronária relacionada ao infarto é essencial para o salvamento de miocárdio isquêmico em pacientes com ...

NEXT trial demonstra não-inferioridade entre os stents com polímero biodegradável (Nobori®) comparados a stents com polímero durável (Xience V® / Promus®) no seguimento de 3 anos
Fundamentos: Dados recentes de metanálise tem levantado dúvidas com relação a segurança dos stents eluidores de fármacos com polímero ...

Estudo DEFLECT III demonstrou que o novo dispositivo de proteção anti-embólica DEFLECTion durante TAVI é factível e efetivo
Fundamentos: A reperfusão rápida da artéria coronária relacionada ao infarto é essencial para o salvamento de miocárdio isquêmico em pacientes com ...

Angiographic TOTAL: Sub angiography studio of TOTAL
Myocardial blush is a predictor of mortality after primary angioplasty. Small studies showed a degree of improvement blush with manual thromboaspiration. The present work is a substudy of the TOTAL ...

IN.PACT Global Study: Pharmacological balloon in long lesions of the Superficial Femoral Artery (SFA)
Long lesions (≥ 15 cm), total occlusions, and in-stent restenosis represent a unique treatment challenge in peripheral vascular disease. IN.PACT Global study is a prospective, multicenter, single ...

PARTNER II: Less oversizing to reduce paravalvular failure with the new generation of SAPIEN 3
The new generation SAPIEN 3 valve was designed to reduce paravalvular aortic regurgitation. The objective of this work was to evaluate the influence of "oversizing" for SAPIEN 3 valve both in ...

TOTAL stroke: increased risk of stroke with thromboaspiration
There are many doubts about the benefit of manual thromboaspiration, not only in terms of improvement of the clinical end point but also the potential risk of stroke. The TOTAL (n = 10732) was a ...

NONSTEMI: Superiority of early angioplasty in non-ST elevation myocardial infarction
The European guidelines recommend revascularization within 24 hours in high-risk patients with No ST segment elevation myocardial infarction. It is unclear whether these patients would benefit from ...

ILUMIEN I: Results of the angioplasty indicated by FFR and controlled by OCT
This is an observational, prospective, multicenter study using optical coherence tomography (OCT) and measurement of fractional flow reserve (FFR) before and after angioplasty. Inpatient following ...

SAPIENS 3: Favorable outcomes with TAVI in intermediate risk patients
Transcatheter aortic valve replacement is a safe and effective alternative to surgery in patients with severe aortic stenosis and high surgical risk as the 5-year results of PARTNER 1 Alternate ...

ILUMIEN II: OCT guided stenting versus IVUS
The main predictor of adverse outcomes (thrombosis and restenosis) after implantation of a stent is the degree of expansion according to published studies using coronary intravascular ultrasound ...

ADVANCE II CoreValve Trial: Results at six months of self-expanding aortic valve
The CoreValve ADVANCE II Trial is a research study of the best practices to implement this device. Those practices included a careful assessment using scan to choose the right valve size, control ...

BVS-STEMI-FIRST OCT study: Bioabsorbable platform in acute myocardial infarction
A bioabsorbable platform implant in the context of ST segment elevation acute myocardial infarction is feasible although the subsequent cicatrization of the artery is not documented. The ...

CoreValve Evolut R CE: Good results at 6 months of the new CoreValve repositionable
This study evaluated the safety and efficacy of the new repositionable self-expanding valve. The primary end point was all-cause mortality and stroke at 30 days. 60 patients were included and the ...

OPINION: optical frequency domain versus IVUS to guide angioplasty
This multicenter, prospective, randomized controlled study was designed to evaluate the noninferiority of guided angioplasty by optical frequency domain (OFDI) compared to IVUS. 800 elective ...

TOTAL OCT: Thrombotic load of culprit lesion using OCT. TOTAL substudy.
The thrombotic load of culprit lesion is unidentified in the context of acute myocardial infarction that vindicates the use of thromboaspiration. This work is a substudy of TOTAL in patients ...

Prótese Edwards Sapien XT e Medtronic Corevalve demonstram desempenho equivalente em 1 ano, em pacientes de alto risco submetidos a TAVI
Fundamentos: Existem poucos dados comparando diferentes próteses valvares (THV) utilizadas nos implantes percutâneos de valva aórtica (TAVI), sendo que as próteses ...

Bons resultados clínicos após implante transcateter da prótese valvar mitral Edwards Fortis®
Fundamentos: A regurgitação mitral severa (MR) representa a segunda doença cardíaca valvar mais prevalente nos países ocidentais. De um terço a metade dos ...

Stent farmacológico em pacientes com risco de sangramento elevado
Fundamentos e objetivos: O uso de stent farmacológico (DES) ao invés de stent “convencional” não farmacológico (BMS) em pacientes com risco de sangramento ...

Antiagregação plaquetária em pacientes no peri-operatório de cirurgias cardíacas e não-cardíacas.
Fundamentos: A gestão otimizada da terapia antiplaquetária perioperatória para pacientes com stents coronários não foi completamente esclarecida. Os dados ...

A localização da lesão coronária associada ao risco de sangramento pode direcionar a duração da dupla terapia antiplaquetária
Fundamentos: A duração ideal da terapia antiplaquetária dupla (DAPT) após implante de stent ainda é controversa e gera muita discussão. As diretrizes ...

NORDIC-BALTIC BIFURCATION IV: 1 ou 2 stents em bifurcação verdadeira?
Fundamentos e Objetivo: O tratamento ideal de bifurcações coronárias com lesões envolvendo um grande ramo lateral (> 2,75 milímetros) não está bem ...

Taxas de trombose de stent em pacientes com STEMI
Fundamentos e objetivos: Em estudos recentes sobre intervenção coronária percutânea primária (PPCI), a bivalirudina em comparação com a heparina tem ...

Prasugrel em pacientes não-respondedores a clopidogrel
Métodos e Resultados: Os não-respondedores ao clopidogrel foram identificados por reatividade plaquetária residual ≥ 70% e o teste foi repetido após a mudança ...

Impacto de dispositivos de oclusão vascular em desfechos a curto e longo prazo após TAVI: resultados do registro EVERY-TAVI
Fundamentos: Os resultados de procedimentos de implante trans-cateter valvar aórtico (TAVI) melhoram com o aumento da experiência dos operadores e com a melhoria técnica das ...

Bons resultados nos procedimentos de implante transcateter valva-em-valva mitral e valva-em-anel mitral
Fundamentos: Válvulas bioprotéticas são cada vez mais implantadas em cirurgias cardíacas abertas. Estas válvulas geralmente falham, resultando na necessidade de ...

Top