Low Gradient Severe Aortic Stenosis despite Preserved Ejection Fraction

Original title: Invasive Hemodynamic Characteristics of Low Gradient Severe Aortic Stenosis Despite Preserved Ejection Fraction. Reference: Juliane Lauten et al. J Am Coll Cardiol 2013;61:1799–808.

Although the pathophysiology, clinical features, and natural course of severe aortic stenosis have been extensively described, management recommendations are still evolving. The current European and American guidelines recommend a valve area cutoff of 1 cm2, or indexed for body surface area of 0.6 cm2/m2, and a ≥40 mm Hg mean pressure gradient, to identify severe aortic stenosis in the presence of normal cardiac output and preserved ejection fraction. However, in a considerable number of patients with normal cardiac output that present aortic stenosis, these appear to be severe judging by their valve orifice area, but moderate (or even mild) judging by their transvalvular gradients.) Because both values usually derived from echocardiography, these cases with low gradients with 40 mm Hg mean gradient and ≥50% ejection fraction were analyzed by echo; they routinely underwent invasive hemodynamic evaluation with retrograde passage of the aortic valve and calculation of aortic orifice area by the Gorlin formula (stroke volume was measured both by oxymetry or by thermodilution in all patients).

Stroke volumes measured by thermodilution were higher than stroke volumes measured by oxymetry (p < 0.0001). Given this difference, results were compared against echo measurements. In this population, the echo area (0.8 ± 0.15 cm²) correlated modestly compared to the invasive measurement of stroke volumes with oxymetry , (0.69 ± 0.16 cm2, bias 0.14 ± 0.17 cm2) or using thermodilution (0.85 ± 0.19 cm2, bias 0.03 ± 0.19 cm2) Mean gradients were very similar by echo and catheterization, with nonsignificant differences. Reclassification to moderate stenosis by hemodynamics occurred in one patient using oxymetry and in 6 patients using thermodilution.

Conclusion: 

Low gradient severe aortic stenosis despite preserved ejection fraction was confirmed by invasive hemodynamics and was not the result of a systematic bias in echo calculation of the aortic orifice area.

Editorial Comment: 

Although both methods present limitations and the area calculation correlates modestly, patient reclassification, that would eventually change therapeutics, is not frequent, especially when oxymetry is used to calcualte stroke volumen.

SOLACI.ORG

More articles by this author

Management of Valve Thrombosis in TAVI: Current Evidence-Based Approach

The expansion of transcatheter aortic valve implantation (TAVI) into younger and lower-risk populations has brought bioprosthetic valve thrombosis to the forefront as a clinically...

Experience with the intra-annular self-expanding Navitor valve: data from the STS/ACC TVT registry

The expansion of TAVI, with the introduction of new-generation devices, has prioritized not only periprocedural safety, but also the preservation of coronary access, more...

The Two Sides of the Coin: What Do CHAMPION-AF and CLOSURE-AF Teach Us About Left Atrial Appendage Closure?

Letter to the editor: Juan Manuel Pérez Asorey Percutaneous left atrial appendage closure (LAAO) is currently going through one of the most interesting stages of...

CLOSURE-AF: Percutaneous Left Atrial Appendage Closure versus Medical Therapy in Atrial Fibrillation

Percutaneous left atrial appendage closure has been proposed as an alternative to anticoagulation in patients with atrial fibrillation and high bleeding risk; however, comparative...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Management of Valve Thrombosis in TAVI: Current Evidence-Based Approach

The expansion of transcatheter aortic valve implantation (TAVI) into younger and lower-risk populations has brought bioprosthetic valve thrombosis to the forefront as a clinically...

Experience with the intra-annular self-expanding Navitor valve: data from the STS/ACC TVT registry

The expansion of TAVI, with the introduction of new-generation devices, has prioritized not only periprocedural safety, but also the preservation of coronary access, more...

Therapeutic strategies in carotid free-floating thrombus: evidence and controversies

Carotid free-floating thrombus (cFFT) is a rare entity with a high embolic risk, associated with acute neurological events such as stroke or transient ischemic...