Paclitaxel eluting balloon . More effective in restenosis of BMS than DES

Original title: A multicenter randomized comparison of paclitaxel-coated balloon catheter with conventional balloon angioplasty in patients with bare-metal stent restenosis and drug-eluting stent restenosis. Referencia: Seiji Habara et al. Am Heart J 2013;166:527-533.e2.

Paclitaxel – eluting balloons have recently emerged as an option for treating in-stent restenosis, both conventional stents ( BMS ) and with drugs (DES ). This study randomized patients 2:1 with in-stent restenosis of BMS or DES ( sirolimus , zotarolimus or everolimus) to angioplasty with paclitaxel eluting balloon ( SeQuent Please balloon catheter , B. Braun Melsungen AG , Vascular Systems, Berlin , Germany) versus conventional balloon . The primary objective of the study was a composite of cardiac death , myocardial infarction and target vessel revascularization at 6 months, point when it was scheduled for angiographic protocol follow-up. 

The study included 208 patients ( 137 received eluting balloon and 71 conventional balloons) . Of the total, 123 injuries were due to restenosis of BMS and 90 by DES restenosis . The type of stent restenosis was similar in both treatment branches. The incidence of the combined end point was 6.6 % for drug balloon versus 31% for conventional balloon group ( p < 0.001 ) . This difference was due to target vessel revascularization since no infarctions or deaths were observed in either group.

In the group of drug balloons restenosis in angiographic follow-up was 1.1% for patients who previously had a BMS versus 9.1% for those with a DES ( p = 0.04 ) . This happens despite the fact that BMS had more extensive and diffuse restenosis at baseline than DES. Drug balloon late lumen loss was lower in the BMS than DES ( 0.05 ± 0.28 mm versus 0.18 ± 0.38mm respectively; P = .03) . 

Conclusion:

The paclitaxel – eluting balloons provide better angiographic and clinical outcomes than conventional balloons in patients  with in-stent restenosis both conventional and drug eluting stents

Editorial Comment:

Striking that standard balloon is still used as a control group to treat in-stent restenosis . After ISAR- DESIRE trials became clear that one DES was best for restenosis of BMS , leaving some unknowns still for DES restenosis ( e.g. same or different drugs tested in the ISAR- DESIRE 2). Despite this, the ISAR- DESIRE 3 also included a conventional balloon branch like this study.

Beyond the expected pharmacological superiority of the balloon , it is important to note the different response to the same when it comes to treating a BMS or DES with restenosis.

SOLACI.ORG

More articles by this author

Evolution of Small Balloon-Expandable Valves

Small aortic rings (20 mm) have posed a significant challenge for both surgery and transcatheter aortic valve implantation (TAVI) due to their association with an...

TCT 2024 | FAVOR III EUROPA

The study FAVOR III EUROPA, a randomized trial, included 2,000 patients with chronic coronary syndrome, or stabilized acute coronary syndrome, and intermediate lesions. 1,008...

TCT 2024 – ECLIPSE: Randomized Study of Orbital Atherectomy vs Conventional PCI in Severely Calcified Lesions

Coronary calcification is associated with stent under-expansion and increased risk of both early and late adverse events. Atherectomy is an essential tool for uncrossable...

TCT 2024 | Use of Drug-Coated Balloons for Side Branch Treatment in Provisional Stenting

In some cases, treating coronary bifurcations with provisional stenting requires side branch stenting, which may lead to suboptimal outcomes. Drug-coated balloons (DCBs) have emerged...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Evolution of Small Balloon-Expandable Valves

Small aortic rings (20 mm) have posed a significant challenge for both surgery and transcatheter aortic valve implantation (TAVI) due to their association with an...

TCT 2024 | Asymptomatic Severe Aortic Stenosis: What Should Be our Approach?

Approximately 3% of the population over 65 years old has aortic stenosis. Current guidelines recommend valve replacement for patients with symptoms or an ejection...

TCT 2024 | FAVOR III EUROPA

The study FAVOR III EUROPA, a randomized trial, included 2,000 patients with chronic coronary syndrome, or stabilized acute coronary syndrome, and intermediate lesions. 1,008...