Paclitaxel eluting balloon . More effective in restenosis of BMS than DES

Original title: A multicenter randomized comparison of paclitaxel-coated balloon catheter with conventional balloon angioplasty in patients with bare-metal stent restenosis and drug-eluting stent restenosis. Referencia: Seiji Habara et al. Am Heart J 2013;166:527-533.e2.

Paclitaxel – eluting balloons have recently emerged as an option for treating in-stent restenosis, both conventional stents ( BMS ) and with drugs (DES ). This study randomized patients 2:1 with in-stent restenosis of BMS or DES ( sirolimus , zotarolimus or everolimus) to angioplasty with paclitaxel eluting balloon ( SeQuent Please balloon catheter , B. Braun Melsungen AG , Vascular Systems, Berlin , Germany) versus conventional balloon . The primary objective of the study was a composite of cardiac death , myocardial infarction and target vessel revascularization at 6 months, point when it was scheduled for angiographic protocol follow-up. 

The study included 208 patients ( 137 received eluting balloon and 71 conventional balloons) . Of the total, 123 injuries were due to restenosis of BMS and 90 by DES restenosis . The type of stent restenosis was similar in both treatment branches. The incidence of the combined end point was 6.6 % for drug balloon versus 31% for conventional balloon group ( p < 0.001 ) . This difference was due to target vessel revascularization since no infarctions or deaths were observed in either group.

In the group of drug balloons restenosis in angiographic follow-up was 1.1% for patients who previously had a BMS versus 9.1% for those with a DES ( p = 0.04 ) . This happens despite the fact that BMS had more extensive and diffuse restenosis at baseline than DES. Drug balloon late lumen loss was lower in the BMS than DES ( 0.05 ± 0.28 mm versus 0.18 ± 0.38mm respectively; P = .03) . 

Conclusion:

The paclitaxel – eluting balloons provide better angiographic and clinical outcomes than conventional balloons in patients  with in-stent restenosis both conventional and drug eluting stents

Editorial Comment:

Striking that standard balloon is still used as a control group to treat in-stent restenosis . After ISAR- DESIRE trials became clear that one DES was best for restenosis of BMS , leaving some unknowns still for DES restenosis ( e.g. same or different drugs tested in the ISAR- DESIRE 2). Despite this, the ISAR- DESIRE 3 also included a conventional balloon branch like this study.

Beyond the expected pharmacological superiority of the balloon , it is important to note the different response to the same when it comes to treating a BMS or DES with restenosis.

SOLACI.ORG

More articles by this author

Pretreatment with DAPT in Acute Coronary Syndrome: An Ongoing Debate?

In acute coronary syndrome (ACS) dual antiplatelet therapy (DAPT) has become a fundamental pillar after percutaneous coronary intervention (PCI), preventing stent thrombosis and acute...

Another Blow for Intra-Aortic Balloon Pumo Counterpulsation? Randomized Study on Its Use in Chronic Heart Failure Progressing to Cardiogenic Shock

Cardiogenic shock (CS) remains a condition with extremely high mortality (around 50%). While most therapies for this pathology have been studied in CS secondary...

Radial Patency in Coronary Procedures: Is Heparin Enough or Should We Aim for Distal Transradial Access?

Transradial access is the preferred route in most coronary procedures due to its proven reduction in mortality compared to transfemoral access. However, one of...

iFR- vs. FFR-Guided Coronary Revascularization: 5-Year Clinical Outcomes

The assessment of coronary stenosis using coronary physiology has become a key tool in guiding revascularization. The two most widely used techniques are fractional...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Pretreatment with DAPT in Acute Coronary Syndrome: An Ongoing Debate?

In acute coronary syndrome (ACS) dual antiplatelet therapy (DAPT) has become a fundamental pillar after percutaneous coronary intervention (PCI), preventing stent thrombosis and acute...

Measuring Post-TAVI Gradients and Their Implications: Are Invasive and Echocardiographic Assessments Comparable?

Transcatheter aortic valve implantation (TAVI) is considered the treatment of choice for a significant proportion of patients with symptomatic aortic stenosis. Outcomes have improved...

Another Blow for Intra-Aortic Balloon Pumo Counterpulsation? Randomized Study on Its Use in Chronic Heart Failure Progressing to Cardiogenic Shock

Cardiogenic shock (CS) remains a condition with extremely high mortality (around 50%). While most therapies for this pathology have been studied in CS secondary...