We evaluated 88 consecutive patients (at this phase) with severe aortic stenosis who received the second-generation device for transapical access. Survival at thirty days was 85.1% with a cardiovascular death rate of 4.8%. No strokes were observed during this period. Average gradient reduction was highly significant, (40.4 to 8.1 mmHg, p <0.001), as well as the effective aortic orifice increase, (0.8 to 1.7 cm2). There were no severe paravalvular aortic regurgitation after implantation. 

Conclusion: This record, that assessed 2nd generation JenaValve device for transapical access, showed excellent safety and efficacy results.


Stephan Ensminger, MD, PHD.
2013-05-22

Original title: First results of the JUPITER registry on long-term performance and safetyof the transapical JenaValve. 

More articles by this author

REPRISE II: results obtained with the new valve according to VARC criteria

The objective was to evaluate the safety and efficacy of the Lotus Valve System to treat patients with severe aortic stenosis and high surgical...

DEFLECT I: cerebral protection device in TAVI

Strokes after TAVI occur in between 3.8 and 6.7% of the cases, with new MRI lesions being almost the rule. The TriGuard EDD device...

DISCOVER: new low profile valve with little post-implant regurgitation

The objective of the study was to assess events after 30 days with the DirectFLOW Medical Valve device in patients with severe aortic stenosis...

PROTAVI-C: Embolic protection during TAVI

Percutaneous aortic valve replacement (TAVI) is a new treatment option for patients that are inoperable or present a high surgical risk. Some studies have...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

T-TEER: Beyond Traditional Pulmonary Hypertension Thresholds

Significant tricuspid regurgitation (TR) is associated with progressive functional deterioration, heart failure (HF) hospitalizations, and increased mortality. In recent years, transcatheter tricuspid edge-to-edge repair...

Is left atrial appendage closure safe in patients with reduced ejection fraction?

Patients with heart failure with reduced ejection fraction (HFrEF) were excluded from the major randomized trials evaluating percutaneous left atrial appendage closure (LAAC), and...

Left Atrial Appendage Closure in Spain: Sustained Growth and Favorable Real-World Outcomes

Oral anticoagulation remains the standard treatment for stroke prevention in patients with atrial fibrillation. However, many patients have a high bleeding risk or contraindications...