COMFORTABLE AMI: A randomized trial comparing a coated stent with biodegradable biolimus polymer (Biomatrix) with an uncoated stent (Gazelle) in patients with AMI with ST segment elevation.

Randomized trial (n = 1161 patients in 16 centers) comparing a coated stent with biodegradable biolimus polymer (Biomatrix) versus uncoated stent (Gazelle) in patients with AMI with ST segment elevation.

While there is no doubt about the effectiveness of first generation SF to reduce the rate of reoperations compared with non-drug eluting stents, there is controversy about its safety in AMI context, especially due to occurrence of events such as very late thrombosis and AMI, (Kalesan B, EHJ 2012; De Luca et al, Arch Int Med 2012) 

The LEADERS study analysis that compared Biomatrix stent with the Cypher stent, demonstrated superiority of Biomatrix at 4 years of follow-up. A subgroup analysis showed Biomatrix particular benefit in patients with AMI. These findings generated the hypothesis that in the AMI context, the use of Biomatrix is

More articles by this author

COMPARE II: A randomized prospective study compared the permanent polymer everolimus-eluting stent with a biodegradable polymer biolimus coated stent.

Randomized prospective study comparing the everolimus-eluting polymer-coated stent versus a biodegradable polymer with biolimus coated stent.  While the use of first generation DES effectively reduces...

FAME II: This randomized trial compared a stent implantation guided by fractional flow reserve (FFR) with optimal medical treatment.

This randomized trial with an initial plan to include 1832 patients, compared stent implantation guided by fractional flow reserve (FFR) versus optimal medical treatment....

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

COILSEAL: Use of Coils in Percutaneous Coronary Intervention, Useful for Complication Management?

The use of coils as vascular closing tool has been steadily expanding beyond its traditional role in neuroradiology into coronary territory, where it remains...

Treatment of In-Stent Restenosis in Small Vessels with Paclitaxel-Coated Balloons

Coronary artery disease (CAD) in smaller epicardial vessels occurs in 30% to 67% of patients undergoing percutaneous coronary intervention and poses particular technical challenges....

Contemporary Challenges in Left Atrial Appendage Closure: Updated Approach to Device Embolization

Even though percutaneous left atrial appendage (LAA) closure is generally safe, device embolization – with 0 to 1.5% global incidence – is still a...