HEAT PPCI: Bivalirudin raises major cardiac events and does not reduce bleeding. The most controversial and criticized study at the ACC 14.

This randomized trial of a single center with consent obtained after randomization compared the use of bivalirudin versus heparin with the use of glycoprotein inhibitors arescue only in patients having ST segment elevation myocardial infarction.The primary efficacy endpoint was a composite of death, stroke, and myocardial revascularization of the target lesion and the primary safety endpoint, major bleeding (BARCcriteria) at 28 days.Using glycoprotein inhibitors was similar with 13.5% in the bivalirudin groupand 15.5% in the heparin group.A total of 1829 patients were included observed an incidence of combined end point of 8.7 % for bivalirudin and 5.7 %for heparin group (p = 0.01). This difference was attributed to thereinfarctionby the increase by 4in in-stent thrombosis in the bivalirudin group (3.4 % versus 0.9 %, P = 0.0001). Major bleeding was similar between groups (3.5 % versus 3.1 %, P = 0.59) .

Conclusion

The use of heparin reduces the event rate compared with bivalirudin to reduce reinfarction caused by stent thrombosis.

Adeel Shahzad
2014-03-31

Title: Unfractionated Heparin versus Bivalirudin in Primary Percutaneous Coronary Intervention: A Unique Randomized Controlled Trial with Consecutive, Unselected Patient Enrollment (using Delayed Consent), Designed to Reflect Real-World, Contemporary Practice (HEAT PPCI)

More articles by this author

MSC -HF Trial: Auto mesenchymal cell transplantation may improve ventricular function in patients with heart failure of ischemic cause

This study is a phase 2, randomized 2:1, double blind, and placebo-controlled included 59 patients with advanced heart failure of ischemic etiology undergoing autologous...

ZEUS Trial: Patients with increased risk of bleeding may benefit from eluting stents Zotarolimus

The use of drug-eluting stents versus bare metal stents is controversial in some clinical situations in patients at high risk of bleeding.This study randomized...

NEXT Trial: Biodegradable polymer stent (Nobori) was similar to the permanent polymer stents (Xience / Promus) at 2 years.

This multicenter work from Japanrandomized 3200 patients to receive biodegradable polymer biolimus eluting stent(Nobori) or everolimus-eluting stent with permanent polymer (Xience / Promus). The...

SIRS Trial: Methylprednisolone does not decrease mortality and increase the risk of stroke in patients undergoing cardiac surgery

Cardiac surgery with cardiopulmonary bypass results in an inflammatory response of the body that is usually associated with adverse outcome. The preventive use of...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long-Term Predictors of Valve Deterioration After TAVI

Transcatheter aortic valve implantation (TAVI) has become an innovative technology for the treatment of patients with severe aortic valve stenosis. Initially implemented in elderly...

Coronary access after TAVI with fourth- and fifth-generation Evolut valves: the EPROMPT-CA study

The expansion of transcatheter aortic valve implantation (TAVI) toward younger and lower-risk patients has increased the relevance of post-procedural coronary access. In this context,...

Morpheus Global Registry: Safety and efficacy of the long tapered BioMime™ Morph stent in complex coronary lesions

Percutaneous coronary intervention in long coronary lesions continues to represent a technical and clinical challenge, in which the use of conventional cylindrical stents may...