Pacing with a 0.035” Guidewire, an Old Technique Coming Back to Simplify TAVR

Pacing with a 0.035” GuidewireThis study seeks to prove the safety and efficacy of rapid left ventricular pacing through a 0.035” guidewire during aortic valvuloplasty and transcatheter aortic valve replacement (TAVR).

 

Right ventricular temporary pacing placed through venous access during aortic valvuloplasty or during TAVR is time-consuming and, above all, associated with cardiac perforation and tamponade.

 

Since both procedures require crossing the aortic valve and placing a left ventricular 0.035” guidewire, the latter can be used for rapid pacing, thus avoiding the need for right ventricular temporary pacing.

 

The cathode (negative pole) of an external temporary pacemaker is placed on the tip of the 0.035” wire and the anode (positive pole) is on a needle inserted into the groin. Insulation is provided by the very same valvuloplasty balloon catheter or valve release system.

Pacing with a 0.035” Guidewire

This technique was used in 38 patients undergoing valvuloplasty and in 87 patients undergoing TAVR in three sites, with a 160-200 beats per minute pacing.

 

A significant drop in blood pressure up to a mean 44 mm Hg was achieved during rapid stimulation. Mean procedural time was 49.7 ± 31 min for valvuloplasty and 68.7 ± 30.9 min for TAVR. A temporary venous pacemaker was required in 12 patients and only 12% of TAVR patients had a femoral central venous catheter.

 

Femoral venous access was not performed in valvuloplasty patients. The only potentially related complication was one case of tamponade (0.8%) 8 hours after the procedure, successfully treated through subxiphoid puncture.

 

In-hospital mortality rates were 2.6% and 4.6% for the valvuloplasty and TAVR groups, respectively.

 

Conclusion

Use of the 0.035” guidewire for rapid pacing during valvuloplasty or TAVR was shown to be simple and reproducible. It prevented complications associated with a right ventricular temporary pacing catheter. In consequence, this technique can simplify and enhance the safety of transcatheter aortic valve replacement.

 

Original title: Rapid Pacing Using the Left Ventricular Guidewire: Reviving an Old Technique to Simplify BAV and TAVI Procedures.

Reference: Benjamin Faurie et al. Catheter Cardiovasc Interv. 2016 Nov 15;88(6):988-993.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...

SCAI 2026 | Can an atrial fixation device prevent complications of transcatheter mitral valve replacement? Analysis of the AltaValve system

Transcatheter mitral valve replacement (TMVR) represents one of the most complex areas within structural interventions. Unlike TAVI, where valvular anatomy typically provides more predictable...

Beyond TAVI: Cardiac Rehabilitation as a Determinant of Clinical Outcomes

Aortic stenosis is an increasingly prevalent condition associated with population aging, with a prevalence of approximately 3.4% in individuals over 75 years of age...

Comparative outcomes between transaxillary approach and thoracotomy-based approaches in TAVI with alternative access

TAVI has become the standard treatment for high-risk aortic stenosis. When transfemoral access is not feasible (approximately 10–15%), alternative approaches are used: transaxillary (subclavian...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

KISS Trial: provisional stenting in non-left main coronary bifurcations — is less more?

Coronary bifurcation angioplasty remains one of the most frequent and technically challenging scenarios in interventional cardiology. Between 15% and 20% of coronary procedures involve...

Complex radial access: a four-step protocol to overcome loops and tortuosity

Radial access is currently the preferred strategy for coronary angiography and percutaneous coronary interventions due to its lower rates of bleeding and vascular complications...

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...