Tricuspid and Bicuspid Valves Present More Coincidences Than Expected

There is more and more positive evidence that new-generation transcatheter valves, originally designed to treat tricuspid aortic valves, work perfectly fine on bicuspid aortic valves.

Más coincidencias de las esperadas entre válvulas bicúspides y tricúspides

A comparison of computerized tomography (CT) scans obtained before and after the procedure showed that the most commonly used devices appear to reshape the aortic annulus to the same degree in both standard patients and in patients with bicuspid valves.


Read also: Transcatheter Reduction or Surgery for Paravalvular Leak Repair?”


The BAVARD multicenter register, presented at PCR London Valves 2017, only looked at imaging results, but all patients included are being tracked in order to obtain information on endpoints such as paravalvular leak, stroke, bleeding, pacemaker implantations, etc.

 

In the current analysis, investigators reviewed pre- and post-implantation CT scans for 97 patients with bicuspid valve disease and compared them with 88 tricuspid aortic stenosis patients. Among these patients, 92% had type 1 bicuspid disease—the most common type seen among people of European descent. The devices used were those most commonly used in Europe (Sapien 3, Evolut R, and Lotus).

 

Measurements of the intercommissural distance were roughly similar between both patient groups, with intercommissural distance in bicuspid patients typically measured 4 mm above the level of the annulus. Annulus size was actually different between these groups, with a mean 23.6 mm for tricuspid patients and a mean 26.9 mm for bicuspid patients.


Read also: Multivessel Disease and Severe Carotid Stenosis: How to Proceed”.


The idea that bicuspid valves have a more elliptically shaped annulus was proven wrong in this work; the annulus shape is exactly the same, although the annulus for bicuspid patients is bigger.

 

Another assumption has been that transcatheter valves are typically implanted at a different height in bicuspid patients, but this was also proven wrong. Implantation depth was 3.4 mm in both patient groups.

 

Device sizing must be determined by the annular dimensions in tricuspid valves and by the intercommissural distance in bicuspid valves.

 

The study can conclude that the second-generation devices used work well in bicuspid patients (at least for type 1 bicuspid disease, which made up most of the cases in this study) and a dedicated device for this patient subgroup seems to be unnecessary.

 

Original title: Bicuspid Aortic Valve Anatomy and Relationship with Devices. The BAVARD Multicenter Registry.

Reference: Tchétché D et al. Presented at: PCR London Valves 2017. September 25, 2017. London, England.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...

SCAI 2026 | Can an atrial fixation device prevent complications of transcatheter mitral valve replacement? Analysis of the AltaValve system

Transcatheter mitral valve replacement (TMVR) represents one of the most complex areas within structural interventions. Unlike TAVI, where valvular anatomy typically provides more predictable...

Beyond TAVI: Cardiac Rehabilitation as a Determinant of Clinical Outcomes

Aortic stenosis is an increasingly prevalent condition associated with population aging, with a prevalence of approximately 3.4% in individuals over 75 years of age...

Comparative outcomes between transaxillary approach and thoracotomy-based approaches in TAVI with alternative access

TAVI has become the standard treatment for high-risk aortic stenosis. When transfemoral access is not feasible (approximately 10–15%), alternative approaches are used: transaxillary (subclavian...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

KISS Trial: provisional stenting in non-left main coronary bifurcations — is less more?

Coronary bifurcation angioplasty remains one of the most frequent and technically challenging scenarios in interventional cardiology. Between 15% and 20% of coronary procedures involve...

Complex radial access: a four-step protocol to overcome loops and tortuosity

Radial access is currently the preferred strategy for coronary angiography and percutaneous coronary interventions due to its lower rates of bleeding and vascular complications...

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...