Ambulatory Continuous Monitoring in Patients with Left Bundle Branch Block After TAVI

The incidence of arrhythmic events up to a year after implantation is high and involves almost half the patients with complete left bundle branch block following the procedure. Significant bradyarrhythmias occur in up to one-fifth of the patients, half of whom ultimately require a pacemaker. These data support the idea of a cardiac monitoring device for close follow-up and expediting pacemaker implantation whenever necessary, while avoiding unnecessary implantations of these devices.

With this work, the authors sought to determine the global arrhythmic burden, the rate of arrhythmias leading to a change in treatment, and the incidence of high-degree atrioventricular block (HAVB) within 12 months of transcatheter aortic valve implantation (TAVI) in patients with new-onset left bundle branch block.

 

This multicenter prospective study included 103 consecutive patients with new-onset left bundle branch block after TAVI, with both balloon-expandable SAPIEN XT/3 valves (n = 53) and self-expanding CoreValve/Evolut R systems (n = 50).


Read also: TCT 2018 | SOLVE-TAVI: Self-Expandable vs. Balloon-Expandable Valves and General vs. Local Anesthesia in One Study.


An implantable monitor (Reveal XT, Reveal Linq) was implanted in all patients at 3 to 6 days after the procedure so as to enable continuous electrocardiogram monitoring for a year. All arrhythmic events were adjudicated in a central electrocardiography core lab. The primary endpoint was the incidence of arrhythmias leading to a change in treatment (e.g., pacemaker implantation) or the onset of HAVB.

 

A total of 1553 new arrhythmic episodes were detected in 44 patients (1443 tachyarrhythmias in 26 patients); these included atrial fibrillation, atrial flutter, atrial tachycardia, and 16 ventricular tachycardias. Furthermore, there were 110 episodes of bradyarrhythmia in 21 patients (54 HAVBs and 56 severe bradycardias).

 

These arrhythmias led to a change in treatment in 18% of patients and to pacemaker or implantable cardioverter-defibrillator implantation in 11% of patients.


Read also: New Atrial Fibrillation After TAVR Indicates Prognosis.


Overall, 77% of patients were asymptomatic regarding these events.

 

Conclusion

There is a high incidence of arrhythmic events after transcatheter aortic valve replacement in patients with complete left bundle branch block after the procedure. One fifth experienced significant bradyarrhythmias that led to pacemaker implantation in half of these cases. The cost-benefit analysis for this implantable device allowing permanent registry for a year is yet to be studied.

 

Original title: Arrhythmic Burden as Determined by Ambulatory Continuous Cardiac Monitoring in Patients with New-Onset Persistent Left Bundle Branch Block Following Transcatheter Aortic Valve Replacement: The MARE Study.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Severe Tricuspid Regurgitation: Surgical vs. Transcatheter Edge-to-Edge Repair

While highly prevalent, tricuspid regurgitation is a notably undertreated valvulopathy. Its progression has been associated with higher mortality and significant disability. According to the...

ACCESS-TAVI: Comparing Post TAVR Vascular Closure Devices

Transcatheter aortic valve replacement (TAVR) is a well-established option to treat elderly patients with severe symptomatic aortic valve stenosis. Technical advances and device development...

Coronary Artery Disease in Aortic Stenosis: CABG + SAVR vs. TAVR + PCI: Data from Spanish Centers

Multiple randomized studies have shown comparable or superior efficacy of transcatheter aortic valve replacement (TAVR) vs. coronary artery bypass graft (CABG).  However, many of...

TCT 2024 | TRISCEND II: A New Hope in Percutaneous Tricuspid Valve Replacement

Advanced tricuspid regurgitation (TR) is a debilitating disease associated with heart failure and increased mortality.  Edge-to-edge repair has been shown to improve both clinical condition...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Severe Tricuspid Regurgitation: Surgical vs. Transcatheter Edge-to-Edge Repair

While highly prevalent, tricuspid regurgitation is a notably undertreated valvulopathy. Its progression has been associated with higher mortality and significant disability. According to the...

ACCESS-TAVI: Comparing Post TAVR Vascular Closure Devices

Transcatheter aortic valve replacement (TAVR) is a well-established option to treat elderly patients with severe symptomatic aortic valve stenosis. Technical advances and device development...

Endovascular Treatment of Iliofemoral Disease for the Improvement of Heart Failure with Preserved Ejection Fraction

Peripheral artery disease (PAD) is a significant risk factor in the development of difficult-to-treat conditions, such as heart failure with preserved ejection fraction (HFpEF)....