TCT 2022 | CLASP II D TRIAL: Transcatheter Edge-to-Edge Repair for Mitral Regurgitation in Patients at Prohibitive Risk

The CLASP IID study was a prospective randomized study to assess the efficacy and effectiveness of the PASCAL transcatheter valve repair system compared with the MitraClip device for patients with degenerative mitral regurgitation (MR) at prohibitive surgical risk.

TCT 2022 | AMULET IDE: Eventos a 3 años con el dispositivo de cierre de orejuela AMULET

The study included Patients at prohibitive surgical risk, candidates for both devices, with MR 3+ to 4+, with ejection fraction >20% and end-diastolic volume <80 mm. Patients with severe right ventricular dysfunction, rheumatic etiology, other concomitant valvulopathies, or with renal dysfunction (filtration rate <25ml/min) were excluded.

The safety primary endpoint (PEP) was the presence of major adverse cardiac events (MACE) at 30 days. MACE were defined as cardiovascular mortality, stroke, acute myocardial infarction (AMI), need for renal replacement therapy, severe bleeding, and valve reintervention (transcatheter or surgical). The efficacy PEP was to assess noninferiority compared with MitraClip regarding the proportion of patients with MR ≤2 at 6 months.

A total of 180 patients were included: 117 for the Pascal device (Pascal and Pascal ACE), and 63 for the MitraClip device (MitraClip NT, NTR, XTR, XTW). Mean patient age was 81 years old; 67% of patients were male and the functional class was III/IV in 61% of cases.

Read also: TCT 2022 | AMULET IDE: Events at 3 Years Using the AMULET Appendage Closure Device.

Upon analysis of the safety PEP, there was an incidence of 3.4% for the Pascal device compared with 4.8% for the MitraClip (difference -1.3%). When comparing efficacy, the presence of residual MR ≤2+ at 6 months was observed in 96.5% of patients with the PASCAL device and 96.8% with MitraClip (difference -0.3%). In terms of functional class, patients with the PASCAL device presented functional class I/II in 86.1% vs. 94% with the MitraClip.

Authors conclusions

The CLASP IID study achieved its primary endpoint of efficacy and effectiveness, demonstrating fewer adverse events at 30 days, and a significant and sustained reduction of MR ≤2 in 97.7% of cases. In turn, patients experienced significant symptomatic improvement in their functional capacity and quality of life, making it an alternative for patients at prohibitive risk.

Dr. Omar Tupayachi

Dr. Omar Tupayachi.
Member of the Editorial Board of SOLACI.org.

Font: CLASP II D Trial: A Randomized Comparison Of Transcatheter Edge-To-Edge Repair Devices For Degenerative Mitral Regurgitation – Clinical Outcomes And Echo Findings presentado por Scott Lim en TCT Congress 22, Boston, EE. UU., 17 septiembre de 2022.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

TCT 2024 | TRISCEND II

This randomized study included 400 patients; 267 were treated with EVOQUE valve and 133 with optimal medical treatment (OMT). After one-year follow-up, there were no...

TCT 2024 – ACCESS-TAVI: Comparing Percutaneous Access Closure Strategies After TAVI

Vascular access complications following transcatheter aortic valve implantation (TAVI) remain common. However, few studies compare vascular access closure methods.  Based on the CHOICE-CLOSURE and MASH...

TAVR in Young Low-Risk Patients

Transcatheter aortic valve replacement (TAVR) has established itself as an effective strategy for the treatment of severe aortic stenosis across different risk groups. While previous...

TAVR and Atrial Fibrillation: What Anticoagulants Should We Use?

The prevalence of atrial fibrillation (AF) in TAVR patients ranges from 15 to 30%, depending on series. This arrhythmia has been associated to higher...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

TCT 2024 | FAVOR III EUROPA

The study FAVOR III EUROPA, a randomized trial, included 2,000 patients with chronic coronary syndrome, or stabilized acute coronary syndrome, and intermediate lesions. 1,008...

TCT 2024 | TRISCEND II

This randomized study included 400 patients; 267 were treated with EVOQUE valve and 133 with optimal medical treatment (OMT). After one-year follow-up, there were no...

TCT 2024 – ACCESS-TAVI: Comparing Percutaneous Access Closure Strategies After TAVI

Vascular access complications following transcatheter aortic valve implantation (TAVI) remain common. However, few studies compare vascular access closure methods.  Based on the CHOICE-CLOSURE and MASH...