Clinical Impact of Coronary Artery Disease on Results After TAVR

Coronary artery disease (CAD) coexists with aortic stenosis in about half the patients who suffer the latter. These patients receiving antiplatelet therapy are at a higher risk of periprocedural bleeding—one of the most frequent complications in patients who undergo transcatheter aortic valve replacement (TAVR).

Impacto clínico de la enfermedad coronaria en los resultados luego del TAVI

One way of limiting the risk for bleeding is choosing the right anticoagulant agent during the procedure. Currently, experts recommend using unfractionated heparin. However, a possible alternative that has reduced the risk for bleeding in patients undergoing coronary angioplasty is bivalirudin, a non-reversible short-action direct thrombin inhibitor.

The aim of this multicenter, randomized, controlled, open-label study was to evaluate the impact of CAD on clinical results after TAVR, and to determine whether CAD has an impact on periprocedural anticoagulant therapy using bivalirudin vs. unfractionated heparin.

The primary endpoint (PEP) was a composite of cardiac adverse events (net-adverse clinical effect, NACE) defined as all-cause mortality, acute myocardial infarction (AMI), stroke, and major bleeding (BARC ≥3b) at 30 days after TAVR. The secondary endpoints (SEP) included major adverse cardiac events (MACE) defined as all-cause mortality, AMI, stroke, acute renal failure, major vascular complications, and life-threatening bleeding (according to VARC criteria).

The study randomized 801 patients, 54.6% with CAD and 45.5% free of CAD. Patients were further randomized to bivalirudin and unfractionated heparin. Mean patient age was 82 years, and most subjects were men. CAD patients were more frequently overweight men. They also had higher EUROSCORE log and greater comorbidities, such as anemia, peripheral arterial disease, and low ejection fraction.

Read also: CTO: Length’s Impact on Success.

Results showed no differences in terms of NACE (15.3% vs. 14.6%; p = 0.761) or BARC ≥3b bleeding (8.9% vs. 10.2%; p = 0.551) at 30 days for patients with or without CAD. The AMI rate was higher in patients with CAD (p = 0.009), and so was the development of acute renal failure (p = 0.048).

There were no differences either in NACE at 30 days (13.9% vs. 16.8%; odds ratio [OR] = 0.80; 95% confidence interval [CI]: 0.47– 1.35) or BARC ≥3b bleeding (7.2% vs. 10.7%; OR = 0.64, 95% CI: 0.33–1.25) among CAD patients who received bivalirudin or unfractionated heparin. The only finding was an increase in the rate of acute renal failure in patients who received bivalirudin (22.9% vs. 15%; OR = 1.69, 95% CI: 1.03–2.75).

Conclusion

The presence of CAD did not have an impact on NACE or periprocedural bleeding at 30 days after TAVR. There were also no differences between using bivalirudin or unfractionated heparin regardless of the diagnosis of CAD.

Dr. Andrés Rodríguez

Dr. Andrés Rodríguez.
Member of the Editorial Board of SOLACI.org.

Original Title: Impact of coronary artery disease on clinical outcomes after TAVR: Insights from the BRAVO‐3 randomized trial. 

Reference: Daniel Feldman MD et al Catheter Cardiovasc Interv. 2023;1–10.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Severe Tricuspid Regurgitation: Surgical vs. Transcatheter Edge-to-Edge Repair

While highly prevalent, tricuspid regurgitation is a notably undertreated valvulopathy. Its progression has been associated with higher mortality and significant disability. According to the...

ACCESS-TAVI: Comparing Post TAVR Vascular Closure Devices

Transcatheter aortic valve replacement (TAVR) is a well-established option to treat elderly patients with severe symptomatic aortic valve stenosis. Technical advances and device development...

Coronary Artery Disease in Aortic Stenosis: CABG + SAVR vs. TAVR + PCI: Data from Spanish Centers

Multiple randomized studies have shown comparable or superior efficacy of transcatheter aortic valve replacement (TAVR) vs. coronary artery bypass graft (CABG).  However, many of...

TCT 2024 | TRISCEND II: A New Hope in Percutaneous Tricuspid Valve Replacement

Advanced tricuspid regurgitation (TR) is a debilitating disease associated with heart failure and increased mortality.  Edge-to-edge repair has been shown to improve both clinical condition...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Severe Tricuspid Regurgitation: Surgical vs. Transcatheter Edge-to-Edge Repair

While highly prevalent, tricuspid regurgitation is a notably undertreated valvulopathy. Its progression has been associated with higher mortality and significant disability. According to the...

ACCESS-TAVI: Comparing Post TAVR Vascular Closure Devices

Transcatheter aortic valve replacement (TAVR) is a well-established option to treat elderly patients with severe symptomatic aortic valve stenosis. Technical advances and device development...

Endovascular Treatment of Iliofemoral Disease for the Improvement of Heart Failure with Preserved Ejection Fraction

Peripheral artery disease (PAD) is a significant risk factor in the development of difficult-to-treat conditions, such as heart failure with preserved ejection fraction (HFpEF)....