Use of Drug-Coated Balloons in De Novo Lesions in Large Coronary Vessels

Drug-coated balloon (DCB) angioplasty is emerging as a novel treatment for coronary artery disease. Studies evaluating this strategy have demonstrated clinically non-inferior outcomes compared with those of drug-eluting stent (DES) implantation in patients with in-stent restenosis and de novo disease in small vessels. However, evidence for the use of DCBs in large coronary vessels is limited.

Utilización de balones cubiertos de fármacos en lesiones de novo en grandes vasos coronarios

Observational, retrospective cohort study DCB 3.0 included a total of 93 consecutive patients with coronary artery disease who were treated with DCB angioplasty for de novo lesions (n = 100) in large coronary vessels at two medical centers, from July 2020 to June 2022.

Inclusion criteria for this study were as follows: 1) presence of a de novo lesion in a vessel with a diameter greater than 3.0 mm, and 2) angioplasty using a DCB with a diameter of 3.0 mm or more, regardless of simultaneous DES implantation.

Patients included in the study had an average age of 68 ± 11 years, and most of them were men. The average SYNTAX score was 22 and, in 83% of cases, the clinical presentation was chronic coronary syndrome. The most frequently treated artery was the anterior descending artery, in 48% of patients, followed by the circumflex artery. The average lesion length was 45 ± 26 mm, and the treated vessels had an average diameter of 3.2 ± 0.3 mm.

Read also: Prognostic Impact of SYNTAX and SYNTAX II Scores in Patients with Acute Myocardial Infarction.

In 70% of the lesions (n = 70), the intention-to-treat (ITT) strategy applied was DCB angioplasty only, while 6% of cases (n = 6) underwent rescue DES implantation. In the remaining lesions (30%), the chosen alternative was a hybrid DCB+DES strategy, which tended to be longer (59.9 ± 22.5 mm vs. 38.1 ± 25.8 mm; p <0.001). Intravascular ultrasound was used in 40% of cases.

Most of the DCBs used were coated with sirolimus (77%), while paclitaxel-coated balloons were used in 18% of cases. The average number of DCBs per lesion was 1.4 ± 0.8. The balloons used had a diameter of 3.1 ± 0.3 mm and a length of 35 ± 22 mm, and were inflated to a pressure of 12 ± 3 atm. The incidence of angiographically evident coronary artery dissection was 52% (n = 52). The mean follow-up for this cohort was 350 days.

Regarding outcomes, the incidence of treated vessel failure was 5.1%: 1.5% in the DCB group and 10.7% in the DCB + DES hybrid group (P = 0.0073). There were no cases of cardiac death or myocardial infarction in the treated vessel. The incidence of revascularization in the treated vessel was 6.6%.

Read also: Coronary Artery Calcium on Non–ECG-Gated Chest CTs: Mere Finding or Therapeutic Opportunity?

The key findings of this study suggest that DCB angioplasty, whether alone or in combination with DES implantation, is safe and effective for the treatment of long de novo lesions in large coronary vessels, potentially reducing the need for DES implantation. Results from a prospective study (Colombo A. et al. Drug-coated balloons as a first choice for patients with de novo lesions: pros and cons. Eurointervention) are expected to provide more robust evidence for this strategy in the future.

Dr. Andrés Rodríguez

Dr. Andrés Rodríguez.
Member of the Editorial Board of SOLACI.org.

Original Title: Immediate and follow-up outcomes of drug-coated balloon angioplasty in de novo long lesions on large coronary arteries.

Reference: Pier Pasquale Leone MD, MSc et al EuroIntervention 2023;19.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

COILSEAL: Use of Coils in Percutaneous Coronary Intervention, Useful for Complication Management?

The use of coils as vascular closing tool has been steadily expanding beyond its traditional role in neuroradiology into coronary territory, where it remains...

Treatment of In-Stent Restenosis in Small Vessels with Paclitaxel-Coated Balloons

Coronary artery disease (CAD) in smaller epicardial vessels occurs in 30% to 67% of patients undergoing percutaneous coronary intervention and poses particular technical challenges....

Coronary Perforations and Use of Covered Stents: Safe and Effective Long-Term Strategy?

Coronary perforations remain one of the most serious complications of percutaneous coronary intervention (PCI), especially in cases of Ellis ruptures type III. In these...

Left Main Coronary Artery Disease: Intravascular Imaging-Guided PCI vs. Coronary Artery Bypass Grafting

Multiple randomized clinical trials have demonstrated superior outcomes with coronary artery bypass grafting (CABG) vs. percutaneous coronary intervention (PCI) in patients with left main...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

COILSEAL: Use of Coils in Percutaneous Coronary Intervention, Useful for Complication Management?

The use of coils as vascular closing tool has been steadily expanding beyond its traditional role in neuroradiology into coronary territory, where it remains...

Treatment of In-Stent Restenosis in Small Vessels with Paclitaxel-Coated Balloons

Coronary artery disease (CAD) in smaller epicardial vessels occurs in 30% to 67% of patients undergoing percutaneous coronary intervention and poses particular technical challenges....

Contemporary Challenges in Left Atrial Appendage Closure: Updated Approach to Device Embolization

Even though percutaneous left atrial appendage (LAA) closure is generally safe, device embolization – with 0 to 1.5% global incidence – is still a...