SMART Trial: What is the Best Valve for Small Annuli?

Transcatheter aortic valve intervention (TAVI) has been shown beneficial over the years. However, a significant subgroup of patients with small aortic annulus, which make approximately one third of cases and have a higher incidence in women, face additional challenge, such as higher incidence of mismatch, reduced exercise capacity and shorter durability. 

Anillos aórticos pequeños, ¿Qué válvula deberíamos elegir?

Self-expanding and balloon expandable valves (SEV and BEV) represent different scaffolds and have shown variations in hemodynamic performance. 

In patients with small annuli, these differences can be significant, even though so far it remains unclear what scaffold offers the best benefit. 

This was a 12-month analysis of the SMART trial (Small Annuli Randomized to Evolut or SAPIEN); an international prospective randomized 1:1 study including 715 patients with severe aortic stenosis. Of these, 355 received SEV and the rest BEV.

The valves used were Evolut PRO/PRO+/FX (Medtronic) and SAPIENS 3 and Ultra (Edwards Lifesciences).

Primary outcomes were assessed at 12 months: the clinical end point was a combination of death, disabling stroke, rehospitalization for cardiac failure, and the bioprosthesis dysfunction end point included hemodynamic structural dysfunction (mean gradient ≥20 mmHg), non-structural valve dysfunction (mismatch or aortic regurgitation at least moderate), valve thrombosis, endocarditis or reintervention.

Read also: ACC 2024 | REDUCE AMI: Beta-Blockers after Myocardial Infarction and Preserved Ejection Fraction.

There were no differences between the populations. Mean age was 80, 86% were women, mortality STS was 3.3%, most were hypertensive, 32% was diabetic, 18% had COPD, 12% had suffered stroke, 4% had chronic kidney disease, 20% atrial fibrillation, 7% acute myocardial infarction and ejection fraction was 61%.

The presence of complete right bundle branch block was 6% and atrial fibrillation was 19%.

SEV valves were mostly 26 mm (68%) and fewer were 29 mm, while the most used BEV was 23 mm (90%) and the rest were 20 mm.

After a year, clinical primary end point resulted  9.4% among SEV patients vs. 10.6% for BEV patients (difference, −1.2 percentage points; CI 90%, −4.9 to 2.5; P<0.001 for non-inferiority; hazard ratio, 0.90; CI 95%, 0.56 to 1.43), but the bioprosthesis dysfunction end point favored SEV (9.4% for SEV vs 41.6% for BEV; a difference of −32.2 percentage points; CI 95%, −38.7 to −25.6; P<0.001).

Read also: Peripheral Vascular Disease: Our Reality in Latin America, with the LATAM SOLACI Peripheral Registry.

As regards the clinical end point, analyzed separately, there were no differences in mortality, stroke or rehospitalization for cardiac failure, but there was in valve dysfunction end point, seeing as SEV presented hemodynamic structural dysfunction (3.2% vs 32.2%, a −29.1 difference in percentage points; CI 95%, −34.6 to −23.5), and nonstructural dysfunction (5.9% vs 18.2%; a −12.3 difference in percentage points; CI 95%, −17.6 to −7.0), with no difference in endocarditis, valve thrombosis or reintervention. 

The echocardiographic analysis showed valve area was larger among SEV patients (1.99 cm2 vs 1.5 cm2, p<0.0001), and mean gradient higher (7.7 mmHg vs 15 mmHg, p<0.0001).

Conclusion

Among patients with severe aortic stenosis and small annulus undergoing TAVR, supra-annular self-expanding valves were not inferior vs balloon expandable valves as regards clinical evolution, but resulted superior as regards bioprosthetic valve dysfunction, at 12 months. 

Dr. Carlos Fava - Consejo Editorial SOLACI

Dr. Carlos Fava.
Member of the Editorial Board of SOLACI.org.

Original Title: Self-Expanding or Balloon-Expandable TAVR in Patients with a Small Aortic Annulus.

Reference: H.C. Herrmann, et al. NEJM DOI: 10.1056/NEJMoa2312573.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Embolization of Left Atrial Appendage Closure Devices: Predictors, Prevention, and Management Strategies

Atrial fibrillation is associated with an increased risk of stroke and, in patients with contraindications to anticoagulation, percutaneous left atrial appendage closure represents an...

Coronary revascularization before TAVI: prior PCI or conservative management?

The coexistence of coronary artery disease (CAD) in patients with severe aortic stenosis undergoing TAVI is common, with a reported prevalence ranging from 30%...

Percutaneous Mechanical Aspiration versus Surgical Treatment of Tricuspid Valve Endocarditis

Tricuspid valve infective endocarditis (TVIE) accounts for approximately 5% to 10% of all cases of infective endocarditis. Surgical treatment remains the standard therapy in...

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

ACVC 2026 | CELEBRATE Trial: Prehospital Zalunfiban Use in STEMI

Optimizing antithrombotic therapy in the prehospital phase of ST-segment elevation myocardial infarction (STEMI) remains challenging due to the delayed onset of action of P2Y12...

ACVC 2026 | BOX Substudy: Mean Arterial Pressure Targets in Cardiogenic Shock After OHCA

Hemodynamic management of cardiogenic shock following ischemic out-of-hospital cardiac arrest (OHCA-AMICS) remains an unresolved issue, particularly regarding optimal mean arterial pressure (MAP) targets and...

ACVC 2026 | FLASH Registry European Cohort: Mechanical Thrombectomy in Pulmonary Embolism

The management of intermediate-high and high-risk pulmonary embolism (PE) remains an area of therapeutic uncertainty, particularly in patients with right ventricular (RV) dysfunction, in...