Edge-to-Edge Repair for Right Ventricular Function Deterioration

Tricuspid regurgitation (TR) has been associated with worse survival and hospitalization for cardiac failure (CF). The current guidelines recommend surgery as treatment, despite its 8 – 15% 30-day mortality rate. And there is no mention of a transcatheter intervention, especially for patients with severe TR and right ventricular deterioration. 

La insuficiencia renal post tratamiento borde a borde tricuspídeo impacta en el pronóstico

Several percutaneous intervention devices have recently been developed. Edge-to-edge devices have been the most assessed, with promising results in high risk populations presenting multiple comorbidities. 

There are a few studies on transcatheter edge-to-edge repair (TEER) for TR; however, its evolution and safety, especially in patients with right ventricular function deterioration (RV), remain unclear.

This study looked at 262 patients undergoing tricuspid TEER, 44 (16.8%) presenting right ventricular function deterioration (RVFD), defined as tricuspid annular plane systolic excursion (TAPSE) <17 mm and right ventricular functional area change (RVFAC) <35%. 

Patient mean age was 79, 49% were men, with EuroSCORE II 6.2%. 84% presented hypertension, 23.3% diabetes, 93% atrial fibrillation, 24% MI, 31% prior pacemaker, and 10% stroke. Creatinine clearance was 50 ml/min, NT pro BNP was 2039 and bilirubin was 0.9.

Read also: Cardioband in Tricuspid Valve Regurgitation.

Left ventricular ejection fraction was lower in patients with RVFD (56% vs 49%, p<0.001), as was TAPSE (19 vs 13, p<0.001) and RVFAC (46 vs 29, p<0.001). TR was severe in 53%, massive in 37% and torrential in 10%.

MitraClip were implanted in 36.6%, TriClip in 36.3% and Pascal in 7.1%. Procedural success was 94% and device per patient was average 1.8. Echo-Doppler 4 days after procedure revealed patients with no right ventricular function deterioration saw a decline in TAPSE and RVFAC (TAPSE, 19.0 vs 17.9 mm; P=0.001; RVFAC, 46.2% vs 40.3%; P<0.001). This was not observed in patients with deteriorated RVFAC (TAPSE, 13.2 vs 15 mm; P=0.011; RVFAC, 29.6% vs 31.6%; P=0.14).

At 30 days, there was no difference in mortality between patients with conserved RV function or RVFAC respectively, also no difference in incidence of stroke, conversion to surgery, major bleeding, kidney function deterioration, pericardial effusion or need for transfusion. 76% presented TR ≤2+.

Read also: Prehospital Crushed vs. Integral Prasugrel in STEMI Patients with Large Myocardial Area at Risk.

At two years, mortality was higher in patients with deteriorated RVFAC (56.3% vs 27%, p<0.001), as was cardiovascular mortality (39% vs 14%, p<0.001) and hospitalization for cardiac failure (49.1% vs 29.1%, p=0.007). Both groups improved their functional class.

After multivariable analysis at 2 years, mortality was associated with TAPSE, RVFAC, left ventricular function and glomerular filtration. 

Conclusion

Edge-to-edge repair is safe and feasible for tricuspid regurgitation in patients with right ventricular function deterioration. Right ventricular function decline was observed in patients with conserved right ventricular function but not in patients with deteriorated right ventricular function. 

Dr. Carlos Fava - Consejo Editorial SOLACI

Dr. Carlos Fava.
Member of the Editorial Board of SOLACI.org.

Original Title: Outcomes of Transcatheter Tricuspid Edge-to- Edge Repair in Patients With Right Ventricular Dysfunction

Reference: Johanna Vogelhuber, et al. Circ Cardiovasc Interv. 2024;17:e013156. DOI: 10.1161/CIRCINTERVENTIONS.123.013156.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Transradial Aortic Valvuloplasty: Is Minimalism Worth It?

Balloon aortic valvuloplasty (BAV) has historically been used either as a bridge strategy, an assessment tool, or even palliative treatment in severe aortic stenosis...

Atrial Fibrillation After Percutaneous Patent Foramen Ovale Closure: Cohort Study with Continuous Implantable Cardiac Monitoring

Atrial fibrillation (AF) is a recognized complication following percutaneous closure of a patent foramen ovale (PFO), with reported incidences of up to 30% during...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Coronary Perforations and Use of Covered Stents: Safe and Effective Long-Term Strategy?

Coronary perforations remain one of the most serious complications of percutaneous coronary intervention (PCI), especially in cases of Ellis ruptures type III. In these...

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....