One-Year Results of ENCIRCLE: Percutaneous Mitral Valve Replacement in Patients Ineligible for Surgery or TEER

Symptomatic mitral regurgitation (MR) in patients who are not candidates for surgery or transcatheter edge-to-edge repair (TEER) remains a highly complex clinical scenario associated with poor prognosis. Although TEER has demonstrated benefit in selected populations, a significant proportion of patients present with unfavorable anatomy or comorbidities that limit its indication.

The development of transcatheter mitral valve replacement (TMVR) via a fully percutaneous transseptal approach represents a potentially superior strategy, allowing for more effective elimination of regurgitation. However, to date, available evidence has mainly derived from feasibility studies or devices requiring transapical access, an approach associated with higher morbidity and mortality.

The ENCIRCLE study is the first trial to evaluate a fully percutaneous transseptal system in a native, non-calcified mitral valve. Its objective was to assess the safety and efficacy at one year of the SAPIEN M3 system for TMVR.

This was a prospective, multicenter, single-arm study conducted at 56 centers across six countries. Patients ≥18 years old, with NYHA functional class ≥II, moderate-severe or severe MR, and deemed unsuitable for surgical replacement or TEER by the Heart Team were included.

Read also: Can Coronary CT Angiography Replace Invasive Coronary Angiography in Pre-TAVI Coronary Assessment?

The primary endpoint was a non-hierarchical composite of all-cause death or heart failure (HF) rehospitalization at one year, compared against a prespecified performance goal of 45%.

Among 1,171 patients screened, 299 were treated, achieving a 96% successful device implantation rate. The mean age was 77 years; 71% had a high symptomatic burden (NYHA III–IV), and the mean STS score was 6.6%.

There were no intraprocedural deaths, no significant left ventricular outflow tract obstruction, and no conversions to surgery. Thirty-day mortality was 0.7%. At one year, the incidence of the primary endpoint was 25.2% (95% CI 20.6–30.6), significantly lower than the prespecified performance goal of 45% (p<0.0001). All-cause mortality was 13.9% (95% CI 10.4–18.5), and HF rehospitalization occurred in 16.7% (95% CI 12.8–21.6).

Read also: Valve-in-Valve in Small Surgical Aortic Bioprostheses: Balloon-Expandable or Self-Expanding? Three-Year Results from the LYTEN Trial.

From a hemodynamic standpoint, 96% of patients had MR ≤1+ at one year (79% with no or trivial MR and 16% with mild MR). In addition, a reduction in left ventricular end-diastolic volume and an improvement in stroke volume were observed. Clinically, 73% improved by at least one NYHA functional class (p<0.0001), with a significant increase in quality of life as measured by the KCCQ-OS (mean increase of 18.4 points; p<0.0001).

Regarding adverse events, the rate of disabling stroke at one year was 3.9%, clinically significant valve thrombosis occurred in 6.7%, and mitral reintervention was required in 6.4% of patients.

Conclusions

In patients with symptomatic MR who were not candidates for surgery or TEER, transseptal transcatheter mitral valve replacement with the SAPIEN M3 system was associated with a significantly lower rate of death or HF rehospitalization at one year compared with the prespecified performance goal, along with very low early mortality and a sustained, near-complete reduction of mitral regurgitation.

Original Title: Percutaneous transcatheter valve replacement in individuals with mitral regurgitation unsuitable for surgery or transcatheter edge-to-edge repair: a prospective, multicountry, single-arm trial.

Reference: Guerrero ME, Daniels DV, Makkar RR, Thourani VH, Asch FM, Pham M, Muhammad KI, Greenbaum AB, Vasquez A, Oldemeyer JB, Dahle TG, Rihal C, Morse MA, Rodriguez E, O’Neill BP, Russo M, Whisenant B, Yadav P, Yu X, Wang DD, Makar M, Baran DA, Mahoney P, Reddy G, Blanke P, Webb J; ENCIRCLE Trial Executive Committee and Study Investigators. Percutaneous transcatheter valve replacement in individuals with mitral regurgitation unsuitable for surgery or transcatheter edge-to-edge repair: a prospective, multicountry, single-arm trial. Lancet. 2025 Nov 29;406(10519):2541-2550. doi: 10.1016/S0140-6736(25)02073-2. Epub 2025 Oct 27. Erratum in: Lancet. 2025 Nov 29;406(10519):2540. doi: 10.1016/S0140-6736(25)02380-3. PMID: 41167201.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

Dr. Omar Tupayachi
Dr. Omar Tupayachi
Member of the Editorial Board of solaci.org

More articles by this author

SAFE-PROTECT at 12 Months: AnchorMan vs. Watchman for Left Atrial Appendage Closure

Percutaneous left atrial appendage (LAA) closure is an alternative therapeutic strategy for reducing the risk of stroke in patients with atrial fibrillation (AF). Randomized...

Clinical and haemodynamic outcomes with contemporary intra- vs. supra-annular valves: The HERA-TAVI Registry

According to the latest European guidelines, transcatheter aortic valve implantation (TAVI) is the recommended treatment for patients aged ≥70 years with symptomatic severe aortic...

Redo-TAVI with SAPIEN 3: 30-Day Outcomes

The indications for transcatheter aortic valve implantation (TAVI) have rapidly expanded to include intermediate- and low-risk patients, extending its use to younger individuals with...

Coronary artery disease progression after transcatheter aortic valve replacement: quantitative coronary angiography and Quantitative Flow Ratio analysis

The coexistence of coronary artery disease and severe aortic stenosis is common among patients undergoing transcatheter aortic valve replacement (TAVR). However, the impact of...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

Shortened DAPT Regimens According to the PRECISE-HBR Score

The optimal duration of dual antiplatelet therapy (DAPT) following percutaneous coronary intervention depends on balancing the prevention of ischemic events against the risk of...

SAFE-PROTECT at 12 Months: AnchorMan vs. Watchman for Left Atrial Appendage Closure

Percutaneous left atrial appendage (LAA) closure is an alternative therapeutic strategy for reducing the risk of stroke in patients with atrial fibrillation (AF). Randomized...

Clinical and haemodynamic outcomes with contemporary intra- vs. supra-annular valves: The HERA-TAVI Registry

According to the latest European guidelines, transcatheter aortic valve implantation (TAVI) is the recommended treatment for patients aged ≥70 years with symptomatic severe aortic...