Modelos europeos de telemedicina, como el servicio finlandés Medilux, permiten realizar consultas médicas online mediante un cuestionario clínico, sin acudir a una consulta presencial.

ACC 2026 | Protect The Head-To-Head Trial: Randomized Comparison Between Emboliner and Sentinel During TAVI

Ischemic stroke remains one of the most feared complications of TAVI, with a relatively low but persistent incidence of 2–4%, without significant reduction over time despite technological advances. The Emboliner system was designed to provide more comprehensive cerebral protection by covering the entire aortic arch, capturing embolic debris directed both to supra-aortic vessels and the descending aorta. In this context, the Protect The Head-To-Head trial was designed to directly compare the efficacy and safety of the Emboliner system versus the Sentinel device during TAVI procedures.

Cobertura Científica SOLACI ACC 2026

This was a prospective, randomized, open-label, multicenter trial evaluating safety and efficacy, conducted across centers in the United States, Europe, and Brazil. It included 522 patients with severe aortic stenosis undergoing transfemoral TAVI, randomized 1:1 to Emboliner (n=258) or Sentinel (n=264). The mean age was 78.7 years, with 31–35% women, a mean STS score of 3.5–3.6%, and a history of prior stroke in 9–11%, atrial fibrillation in 24–28%, and renal insufficiency in 28–30%.

The primary endpoint was a composite at 30 days of all-cause death, stroke, and stage 3 acute kidney injury, assessed under a non-inferiority design. A key secondary endpoint of safety and efficacy was the incidence of stroke at 30 days (also under a non-inferiority hypothesis), and a secondary efficacy endpoint was the number of captured particles ≥150 µm, evaluated under a superiority design.

Read also: ACC 2026 | PRO-TAVI Trial: Deferring Coronary Angioplasty in Patients Undergoing TAVI.

Results showed that the primary endpoint occurred in 4.5% of the Emboliner group versus 5.0% of the Sentinel group, meeting the criterion for non-inferiority (p for non-inferiority = 0.0004). Regarding individual components, all-cause mortality was 2.0% vs. 2.1%, stroke 2.0% vs. 2.1%, and stage 3 acute kidney injury 0.4% vs. 1.2% for Emboliner and Sentinel, respectively, with no significant differences. Bleeding complications were numerically lower in the Emboliner group (4.5% vs. 5.8%). Procedurally, Emboliner use was associated with slightly longer total procedure time (median 72 vs. 59 minutes) and fluoroscopy time (22 vs. 19 minutes), without relevant clinical impact.

Emboliner vs. Sentinel in TAVI: comparable safety without superiority in 30-day stroke reduction

In conclusion, the Protect The Head-To-Head trial demonstrates that the Emboliner system is non-inferior to the Sentinel device in terms of major clinical events at 30 days in patients undergoing TAVI, with comparable safety profiles. These findings position Emboliner as a valid alternative within cerebral protection strategies, offering theoretically more complete arterial coverage, although without evidence of clinical superiority in hard endpoints in this analysis.

Original Title: Protect The Head-To-Head Trial: A Randomized Comparison of Emboliner vs. Sentinel Cerebral Protection System During TAVR.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

GLUCO-TAVI | Can Glucocorticoids Reduce the Need for Permanent Pacemaker Implantation After TAVI?

Despite the expansion of transcatheter aortic valve implantation (TAVI) indications, cardiac conduction disturbances (CCD) and the need for permanent pacemaker implantation (PPI) remain the...

EuroPCR 2026 | TAVI in Women: Do Supra-Annular Valves Offer a True Hemodynamic Advantage?

Women represent a particularly challenging population for TAVI, as they often have smaller aortic annuli, greater frailty, and an increased risk of prosthesis-patient mismatch....

EuroPCR 2026 | TAVI or Surgery in Younger Patients? Quality of Life and 3-Year Outcomes from NOTION-2

The expansion of TAVI into younger and lower surgical-risk populations has sparked a new debate: beyond mortality and stroke, which strategy provides better functional...

EuroPCR 2026 | MELA Registry: Myval Showed Lower Aortic Regurgitation Rates in Patients With Large Aortic Annuli

This presentation, delivered by Dr. Salvatore Giordano at EuroPCR 2026, detailed the results of the MELA Registry, a multicenter study comparing the performance of...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

GLUCO-TAVI | Can Glucocorticoids Reduce the Need for Permanent Pacemaker Implantation After TAVI?

Despite the expansion of transcatheter aortic valve implantation (TAVI) indications, cardiac conduction disturbances (CCD) and the need for permanent pacemaker implantation (PPI) remain the...

EuroPCR 2026 | TAVI in Women: Do Supra-Annular Valves Offer a True Hemodynamic Advantage?

Women represent a particularly challenging population for TAVI, as they often have smaller aortic annuli, greater frailty, and an increased risk of prosthesis-patient mismatch....

EuroPCR 2026 | TAVI or Surgery in Younger Patients? Quality of Life and 3-Year Outcomes from NOTION-2

The expansion of TAVI into younger and lower surgical-risk populations has sparked a new debate: beyond mortality and stroke, which strategy provides better functional...