Implanting a second valve and embolization are two complications that increase mortality

Original title: Determinats and Outcomes of Acute transcatheter Valve-in Valve Therapy or Embolization. Reference: Raj R Makkar, et al. J Am Coll Cardiol 2013;62:418-30

 

Percutaneous aortic valve implantation has proven to be feasible, safe and a successful follow up. Only in a few patients is the two-valve implantation necessary due to bad positioning or embolism but the evolution of these patients has not been studied. In the PARTNER study, (Placement of Aortic Transcatheter Valve Trial Edwards SAPIEN Trans-catheter Heart Valve), 2,554 patients were included. 63 (2.5%) required a second valve implantation within the first (TV-in-TV) and with 26 (1%) embolization occurred (TVE). The valve used in all cases was the Edwards SAPIEN (Edwards Lifesciences, LLC, Irvine, California).

Within the number of patients requiring TV-in TV, 56 were due to severe aortic regurgitation not only because of the bad position of the valve but also for dysfunction of the leaflets. The following served as independent predictors of a second valve; male sex, prior myocardial revascularization surgery, low ejection fraction and moderate to severe mitral regurgitation. Both at 30 days and 12 months, these patients had higher mortality, cardiac mortality, permanent pacemaker and re-hospitalization. TVE was also more frequent immediately after implantation in men with low gradient and a larger aortic annulus. Fourteen were resolved by a percutaneous approach and twelve by surgery. Conversion to surgery had a higher mortality, (33.3% versus 14.3%). Both at 30 days and 12 months the patients with valve embolization had significantly higher mortality, cardiac mortality, stroke and increased vascular and bleeding complications. Both complications required hemodynamic support, more contrast and exposure time to radiation. 

Conclusion:

Device embolization or the need to implant a second valve into the first are both serious TVAR complications that often require multiple valves. This can be caused by both anatomical and technical factors and implies an increase in mortality, which is very important to the proper planning of the procedure. 

Comment:

The proper planning of the procedure is important, taking into account both the anatomical characteristics of the patient and the experience of the surgeons. These two complications are associated with increased mortality and surgery conversion, besides renal aggression due to contrast, greater exposure to rays and hospitalization.

Courtesy of Carlos Fava MD,
Interventional Cardiologist.
Favaloro Foundation. Buenos Aires. Argentina.

Dr. Carlos Fava para SOLACI.ORG

More articles by this author

Can TAVI Be Safely Performed in Patients With Bicuspid Aortic Valve?

Bicuspid aortic valve (BAV) represents an anatomical challenge for transcatheter aortic valve replacement (TAVR) due to the frequent presence of elliptical annuli, fibroc calcific...

Transcatheter Paravalvular Leak Closure: Mid-Term Outcomes and Prognostic Factors

Paravalvular leaks (PVL) are a frequent complication following surgical valve replacement, occurring in 5% to 18% of prosthetic valves. Incidence varies according to valve...

After a Major Bleeding Event in Atrial Fibrillation: When Should Left Atrial Appendage Closure Be Considered?

Atrial fibrillation (AF) in patients who experience a major bleeding event represents a complex clinical scenario in which percutaneous left atrial appendage closure (LAAC)...

New Balloon-Expandable Aortic Valve: 30-Day Outcomes in Patients with Small Aortic Annulus

As transcatheter aortic valve implantation (TAVI) continues to expand toward younger patients with longer life expectancy, factors such as valve hemodynamic performance, durability, and...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Rolling Stone: Registry of Intravascular Lithotripsy vs Atherectomy Use in Complex Calcified Lesions

Severe coronary calcification represents one of the main challenges in performing percutaneous coronary intervention, both due to the higher risk of stent underexpansion and...

Can TAVI Be Safely Performed in Patients With Bicuspid Aortic Valve?

Bicuspid aortic valve (BAV) represents an anatomical challenge for transcatheter aortic valve replacement (TAVR) due to the frequent presence of elliptical annuli, fibroc calcific...

FFR Assessment for the Selection of Hypertensive Patients Who Benefit from Renal Stenting

Atherosclerotic renal artery stenosis (ARAS) represents one of the main causes of secondary hypertension (HTN) and is associated with a higher risk of renal...