Fluorography reduces radiation exposure of patients and operators without affecting the effectiveness of diagnostic coronary angiography

Original title: Effectiveness of Fluorography Versus Cineangiography at Reducing Radiation Exposure During Diagnostic Coronary Angiography. Reference: Shah B et al. Am J Cardiol. 2014 Apr 1;113(7):1093-8.

Coronary angiography is the gold standard for defining obstructive coronary disease. However, radiation exposure remains an unclear and unwanted risk. The aim of this study was to determine whether the new digital fluorography techniques successfully reduce radiation exposure of patients referred for coronary angiography with < 115 cm abdominal circumference and > 60 ml / min glomerular filtration rate where randomized to fluorography (n = 25) or cineangiography (n = 25). The fluorography group underwent coronary angiography using retrospectively stored fluorography with repeat injection under cineangiography only when needed for better resolution per operator’s discretion.  Primary end point was patient radiation exposure measured by radiochromic film.

Secondary end points included secondary radiation measured by kerma area product and air kerma at the interventional reference point (Ka, r) and operator radiation exposure measured by a dosimeter.  

Patient radiation exposure resulted significantly lower in the fluoroscopy group, compared to the cineangiography group (158.2 mGy [76.5-210.2] vs 272.5 mGy [163,3-314] respectively; p=0.001), kerma – area product (1323 mGy . m2 [826-1765] vs 3.451 mGy . m2 [2464-4818]; p < 0,001 ), and Ka, r (175mGy [ 112-252 ] vs 558 mGy [313-621 ]; p < 0.001). This represents a relative reduction of 42 %, 62 % and 69 %, respectively.

Though statistically not significant, operator exposure followed the same trend, (fluorography 2.35 mGy [1.24-6.30] vs cineangiography 5.03 mGy [2,48-7,80], p =0.059). 

Conclusion

Fluorography in a select group of patients during coronary angiography with repeated injection under cineangiography only when necessary, successfully reduced patient radiation exposure.

Editorial Comment:

The new coronary cineangiography has largely overcome several specialty limitations with numerous techniques. One of them is the possibility to store fluoroscopy imaging without the need of cineangiography. In this study we observe fluorography significantly reduces patient exposure and marks a positive trend to reduce operator radiation exposure without affecting diagnostic effectiveness.  In a time when invasive procedures of increased exposure have exponentially grown in number, this choice could have a positive impact both in patients and operators. A Limitation to this practice is that this kind of technology might not be available in all centers. 

Courtesy of Dr Matías Sztejfman
Interventional Cardiologist.
Güemes Hospital.
Buenos Aires, Argentina.

Dr. Matías Sztejfman

More articles by this author

ROLLER COASTR-EPIC22: Comparison of Plaque Modification Techniques in Severely Calcified Coronary Lesions

The presence of coronary calcium significantly limits the success of percutaneous coronary interventions (PCI), primarily due to suboptimal stent expansion. This can lead to...

Early and Late Outcomes with the ABSORB Bioresorbable Scaffold

Coronary angioplasty with drug-eluting stents (DES) is associated with a 2-3% annual incidence of stent-related events, a risk that has not significantly decreased despite...

Is Angioplasty Always Necessary after TAVR?

Courtesy of: Silvina E. Gomez, MD The prevalence of coronary artery disease (CAD) in patients undergoing TAVR is high, ranging from 40 to 70%, according...

Provisional Stenting vs. Two-Stent Technique in Non-Complex Left Main Disease: Three-Year Follow-Up of the EBC-Main Study

In left main coronary artery (LMCA) disease, for lesions of low to intermediate complexity according to the SYNTAX score, percutaneous coronary intervention (PCI) has...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

TAVR in Bicuspid Valves: Higher Prosthesis Mismatch?

TAVR indication is steadily advancing onto younger, lower risk patients.  The presence of bicuspid aortic valves (BAV) has been observed in 0.5% to 2% of...

ROLLER COASTR-EPIC22: Comparison of Plaque Modification Techniques in Severely Calcified Coronary Lesions

The presence of coronary calcium significantly limits the success of percutaneous coronary interventions (PCI), primarily due to suboptimal stent expansion. This can lead to...

Edge-to-Edge Repair in Central and Non-Central Mitral Regurgitation

Mitral regurgitation (MR) is a common condition, with approximately 3.5% prevalence in individuals under 65, increasing to 7.7% in those over 75. It can...