AFIB ABLATION PILOT: Ablation of Atrial Fibrillation by Radiofrequency.

Review: A European multicenter registry, (mainly in France, Italy and Germany), which included 1,410 patients – evidence of real-world – in which ablation performed by radiofrequency had a success rate of 74% (without arrhythmias to 3 months) and a low rate of complications, (2.6%, 0.54% CVA and 0.71% vascular injuries). With patients in whom the procedure was successful, 18% required a second ablation and 51% antiarrhythmic therapy, although the total number of patients in the proportion of patients receiving antiarrhythmic therapy accounted for 32%.

AFIB-PILOT-sildes
Elena Arbelo
2012-08-27

Original title: AFIB ABLATION PILOT: ESC-EURObservational Research Programme: 1-year follow-up of the Atrial Fibrillation Ablation Conducted by the European Heart Rhythm Association

More articles by this author

JAPAN EQ: Cardiovascular risk after natural disasters.

Natural disasters have been associated with an increase in cardiovascular mortality. In the Miyagi area, near the epicenter of an earthquake and tsunami in...

WOEST: Randomized trial that compared dual therapy versus triple therapy on anticoagulated patients.

A multicenter randomized study, (n = 573), that evaluated the role of aspirin in anticoagulated patients undergoing angioplasty. The primary endpoint was the rate...

CORE 320: Diagnostic performance of coronary angiotomography including evaluation of myocardial perfusion versus isolated anatomical assessment.

Review: The CORE-320 multicenter study compared combined angiotomography assessments: anatomical (coronary) and functional (myocardial perfusion) versus anatomical only. For this study, 381 patients who...

PRAGUE-12: Surgical Atrial Ablation: Follow the one-year results.

Review: Two hundred twenty-four patients in a surgical plan, (coronary artery bypass grafting or valve), were randomized to cardiac surgery alone or associated with...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...