CORE 320: Diagnostic performance of coronary angiotomography including evaluation of myocardial perfusion versus isolated anatomical assessment.

Review: The CORE-320 multicenter study compared combined angiotomography assessments: anatomical (coronary) and functional (myocardial perfusion) versus anatomical only. For this study, 381 patients who were evaluated by coronary angiography and non-invasive myocardial perfusion gated SPECT were included. In this study the combined evaluation showed better correlation with the observed measurements in assessing the invasive assessment alone, (AUC 0.87 versus 0.81, respectively, p <0.001). Perfusion data provided during the coronary angiotomography realization allows the combination of fundamental physiological and anatomical data in the decision making for patients with coronary disease.


João A. C.
2012-08-27

Original title: Diagnostic Performance of Combined Noninvasive Coronary Angiography and Myocardial Perfusion Imaging Using 320-row Detector Computed Tomography: The CORE320 Multicenter, Multinational Study

More articles by this author

JAPAN EQ: Cardiovascular risk after natural disasters.

Natural disasters have been associated with an increase in cardiovascular mortality. In the Miyagi area, near the epicenter of an earthquake and tsunami in...

WOEST: Randomized trial that compared dual therapy versus triple therapy on anticoagulated patients.

A multicenter randomized study, (n = 573), that evaluated the role of aspirin in anticoagulated patients undergoing angioplasty. The primary endpoint was the rate...

AFIB ABLATION PILOT: Ablation of Atrial Fibrillation by Radiofrequency.

Review: A European multicenter registry, (mainly in France, Italy and Germany), which included 1,410 patients - evidence of real-world - in which ablation performed...

PRAGUE-12: Surgical Atrial Ablation: Follow the one-year results.

Review: Two hundred twenty-four patients in a surgical plan, (coronary artery bypass grafting or valve), were randomized to cardiac surgery alone or associated with...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

SAPIEN 3 TAVI Durability: Ten-Year Follow-Up in Intermediate-Risk Patients

The durability of transcatheter bioprosthetic valves used in TAVI remains one of the key unanswered questions as indications continue to expand toward patients with...

Aneurysm Sac Regression Predicts Better Clinical Outcomes After EVAR?

Aneurysm sac regression following endovascular abdominal aortic aneurysm repair (EVAR) has been proposed as a marker of favorable remodeling and effective aneurysm exclusion. However,...

Inflammation after TAVI: An Emerging Therapeutic Target?

Conduction disturbances and the need for permanent pacemaker implantation remain common complications following TAVI, with an incidence approaching 15%. Although they have traditionally been...