Long-term results of the RESPECT study favor closure with the Amplatzer device

Courtesy of Dr. José Álvarez.

The RESPECT trial is a multicenter randomized trial with blinded adjudication of end-point events. It randomly assigned patients from 18 to 60 years of age who had a patent foramen ovale (PFO) and a history of cryptogenic ischemic stroke to undergo closure of the PFO with the Amplatzer device plus medical therapy or to receive medical therapy alone (aspirin, warfarin, clopidogrel, or aspirin combined with dipyridamole).

Se publicaron los resultados del estudio RESPECT con excelentes novedades

The efficacy endpoint was a composite of nonfatal ischemic stroke, fatal ischemic stroke, or early death after randomization. The first results of an average follow-up of 2.1 years have been reported previously. The current article includes results from the extended follow-up.

 

Results

The study enrolled 980 patients who were randomized as explained and followed for a mean 5.9 years. Treatment exposure was 3141 patient-years in the device group and 2669 patient-years in the medical-therapy group. This apparently unequal situation was a result of the rate of patients lost to follow-up: 20.8% for the first group and 33.3% for the second.

 

In the intention-to-treat analysis, recurrent ischemic stroke occurred in rates of 0.58 and 1.07 events per 100 patient-years in the device and medical-treatment groups, respectively (hazard ratio [HR]: 0.55; 95% confidence interval [CI]: 0.31 to 0.999; p = 0.046). Although, numerically, the divergence in the incidence of ischemic stroke was small, the relative difference resulted in 45% less events in the group randomized to the device. The prevention of an ischemic stroke event at 5 years required treating 43 patients with the device.


Read also: Amplatzer and Figulla Devices Prove to Be Safe for Percutaneous Patent Foramen Ovale Closure”.


As regards the safety analysis, the rate of venous thromboembolism (a composite of events of pulmonary embolism and deep-vein thrombosis) was higher for the device group than for the medical-therapy group, although, surprisingly, both groups presented a high incidence of thromboembolic disease.

 

Additionally, there were 25 serious procedure-related adverse events, including atrial flutter and fibrillation, cardiac perforation, intracavity thrombosis, ischemic stroke, pulmonary embolism, etc., all of which were resolved during the first hospital stay.

 

Editorial

The Amplatzer PFO Occluder was approved by the FDA for patent foramen ovale closure in October, 2016. Results of the extended follow-up of the RESPECT trial (presented here) are considered beneficial no only due to the number of events prevented, but mainly due to their seriousness (recurrent stroke).


Read also: Is Same-Day Discharge After Angioplasty Safe?”


These results match those of the other two studies published in the same issue of NEMJ: the CLOSE trial, which randomized patients with PFO and interatrial septum aneurysm or PFO and significant shunt, and used several closure devices; and the REDUCE trial, which used the GORE HELEX and CARDIOFORM devices, and in which follow-up included an MRI at 24 months for the detection of asymptomatic ischemic events.

 

The FDA warns that the Amplatzer PFO Occluder device may be used only in patients with cryptogenic stroke after detailed clinical assessment by a cardiologist and a neurologist.

 

Courtesy of Dr. José Álvarez.

 

Original title: Long Term Outcomes of Patent Foramen Ovale Closure or Medical Therapy after Stroke.

Reference: N Engl J Med 2017;377:1022-32


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

One-Year Results of ENCIRCLE: Percutaneous Mitral Valve Replacement in Patients Ineligible for Surgery or TEER

Symptomatic mitral regurgitation (MR) in patients who are not candidates for surgery or transcatheter edge-to-edge repair (TEER) remains a highly complex clinical scenario associated...

Can Coronary CT Angiography Replace Invasive Coronary Angiography in Pre-TAVI Coronary Assessment?

Coronary artery disease coexists in approximately half of patients undergoing transcatheter aortic valve implantation, making coronary assessment prior to the procedure essential. Invasive coronary...

Valve-in-Valve in Small Surgical Aortic Bioprostheses: Balloon-Expandable or Self-Expanding? Three-Year Results from the LYTEN Trial

Dysfunction of small surgical aortic bioprostheses represents a challenging scenario for transcatheter aortic valve replacement in the valve-in-valve setting, due to the higher incidence...

Can TAVI Be Safely Performed in Patients With Bicuspid Aortic Valve?

Bicuspid aortic valve (BAV) represents an anatomical challenge for transcatheter aortic valve replacement (TAVR) due to the frequent presence of elliptical annuli, fibroc calcific...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

OCT- and IVUS-Guided Coronary Angioplasty in Acute Coronary Syndrome: Long-Term Clinical Outcomes

Percutaneous coronary angioplasty (PCI) in patients with acute coronary syndrome (ACS) has reduced mortality in the acute phase. However, recurrent ACS and target vessel...

One-Year Results of ENCIRCLE: Percutaneous Mitral Valve Replacement in Patients Ineligible for Surgery or TEER

Symptomatic mitral regurgitation (MR) in patients who are not candidates for surgery or transcatheter edge-to-edge repair (TEER) remains a highly complex clinical scenario associated...

Can Coronary CT Angiography Replace Invasive Coronary Angiography in Pre-TAVI Coronary Assessment?

Coronary artery disease coexists in approximately half of patients undergoing transcatheter aortic valve implantation, making coronary assessment prior to the procedure essential. Invasive coronary...