Should We Start Thinking Again About Bioresorbable Stents?

Coronary revascularization with drug-eluting stents (DES) is very frequent, especially in acute coronary syndromes, but these metallic stents are permanent foreign bodies that activate the entire inflammatory system.

¿Deberíamos comenzar a pensar nuevamente en los stents bioabsorbibles?

Using bioresorbable stents (BRS) emerged as an alternative to this challenge. Although the initial results of the ABSORB study were not as expected (probably due to a lack of technological development), a new stage in the development of these devices could begin with the new second-generation MAGMARIS stent.

Researchers conducted a single-center analysis of bioresorbable stents implanted from 2012 to 2020 in patients with acute coronary syndromes, following the evolution of the MAGMARIS (MAG) stent in 193 patients and the ABSORB (ABS) stent in 160 patients.

The primary endpoint (PEP) was a safety composite that included all-cause mortality, infarction, and definite or probable thrombosis at 30 days and 1 year. 

The mean age was 65 years, 37% of patients had diabetes, 85% experienced hypertension, 4% suffered from atrial fibrillation, and 38% had a prior angioplasty. Patients who received MAG had higher rates of unstable angina and non-ST-segment-elevation acute myocardial infarction. Similarly, they presented a higher ejection fraction (60% vs. 55%; p < 0.001).

Read also: A Nod to Catheter-Guided Thrombolysis in Pulmonary Thromboembolism.

In all cases, correct pre-dilatation and preparation of the lesion for stent implantation was performed. The most frequently treated artery was the anterior descending (AD): it received 1.2 stents/patient and double antiplatelet therapy.

At 30 days and at 1 year, the PEP was in favor of MAG (0% vs. 3.1%; p = 0.018, and 1.5% vs. 8.1%; p = 0.003), led by the presence of infarction and stent-thrombosis at 30 days in patients who received ABS. 

At 30 days, target-lesion failure was also lower in MAG. At 12 months MAGMARIS presented lower target-lesion failure, led by lower presence of stent-thrombosis and infarction.

Conclusion

Data from the present study show greater safety and a more favorable clinical evolution of the MAGMARIS Magnesium bioresorbable stent compared with the Absorb polymer stent.

Dr. Carlos Fava - Consejo Editorial SOLACI

Dr. Carlos Fava.
Member of the Editorial Board of SOLACI.org.

Original Title: Outcomes of the two generations of bioresorbable scaffolds (Magmaris vs. Absorb) in acute coronary syndrome in routine clinical practice.

Reference: Piotr Rola, et al. Cardiology Journal, ON LINE FIRST DOI: 10.5603/CJ.a2022.0047. 


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

AHA 2024 | SUMMIT

It has been previously shown that the pharmacological treatment of obesity (semaglutide) can reduce cardiovascular events in patients with cardiac failure (CF) and preserved...

AHA 2024 – BPROAD

Hypertension (elevated blood pressure, BP) is the most common comorbidity among diabetic patients and has been associated with higher cardiovascular risk, though as a...

Coronary Artery Disease in Aortic Stenosis: CABG + SAVR vs. TAVR + PCI: Data from Spanish Centers

Multiple randomized studies have shown comparable or superior efficacy of transcatheter aortic valve replacement (TAVR) vs. coronary artery bypass graft (CABG).  However, many of...

Evolution of Small Balloon-Expandable Valves

Small aortic rings (20 mm) have posed a significant challenge for both surgery and transcatheter aortic valve implantation (TAVI) due to their association with an...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...