TAVI in small aortic annulus: self-expanding or balloon-expandable valve in the long term?

Patients with a small aortic annulus (a predominantly female population with a higher risk of prosthesis–patient mismatch) represent a particularly challenging subgroup within TAVI. Self-expanding valves with a supra-annular design have demonstrated better early hemodynamic parameters compared with intra-annular balloon-expandable valves, at the expense of a higher incidence of paravalvular leak and conduction disturbances. However, the long-term clinical impact of these differences had not been clearly established. The aim of this study was to compare five-year clinical and echocardiographic outcomes between balloon-expandable and self-expanding valves in patients with a small aortic annulus undergoing TAVI.

A retrospective analysis was conducted using the RESOLVE registry from Cedars-Sinai Medical Center (Los Angeles, United States), which included 1,392 patients treated between 2015 and 2020. Of these, 423 had a small aortic annulus defined by computed tomography (area <430 mm²). In this cohort, 345 patients received balloon-expandable valves and 78 received self-expanding valves. The median age was 82 years, 78% were women, and surgical risk was intermediate (median STS score 4.37%; IQR 2.87–6.70). Mean body surface area was 1.70 m², and left ventricular ejection fraction was preserved in both groups. The mean aortic annulus area was 381 mm². Contemporary commercial valves were used, predominantly sizes 23 and 26 mm in the balloon-expandable group, and 23, 26, and 29 mm in the self-expanding group.

The primary endpoint was a composite of all-cause mortality, stroke, or hospitalization for heart failure at five years. Secondary endpoints included myocardial infarction, permanent pacemaker implantation, valve reintervention, and structural valve deterioration, defined according to VARC-3 criteria.

Read also: Duration of Smoking Cessation and Risk of Amputation After Revascularization in Critical Limb Ischemia.

Five-year outcomes of TAVI in small aortic annulus: superior hemodynamic performance with self-expanding valves

From a hemodynamic standpoint, self-expanding valves showed a sustained superior performance over time, with significantly lower mean gradients and a larger indexed effective orifice area. At 30 days, the mean gradient was 6 ± 2 mmHg in the self-expanding group compared with 12 ± 3 mmHg in the balloon-expandable group (p<0.001), a difference that persisted at five years (6 ± 3 mmHg vs 13 ± 4 mmHg; p<0.001). The indexed effective orifice area was also greater with self-expanding valves (0.9 ± 0.2 cm²/m² vs 0.7 ± 0.2 cm²/m²; p=0.025). However, self-expanding valves were associated with a higher rate of moderate-to-severe paravalvular leak (7.7% vs 1.5%; p<0.001) and a greater need for post-dilatation (25.6% vs 2.3%; p<0.001).

Regarding clinical outcomes, at five years the primary endpoint occurred in 39.7% of patients with balloon-expandable valves and in 41.1% of those with self-expanding valves, with no statistically significant differences (adjusted HR 1.65; 95% CI 0.88–3.09; p=0.11). All-cause mortality was comparable between both groups (24.9% vs 28.2%; p=0.09), as were the rates of stroke, myocardial infarction, rehospitalization for heart failure, valve reintervention, and structural valve deterioration, which remained low and similar (19.7% vs 15.4%; p=0.64).

Read also: Conservative management of endoleaks in complex aortic endografts under CT angiography follow-up.

The most clinically relevant difference was observed in conduction disturbances: permanent pacemaker implantation was significantly more frequent in the self-expanding valve group (17.9% vs 6.1%), with an adjusted risk more than four times higher (HR 4.03; 95% CI 1.90–8.54; p<0.001). Additionally, a higher incidence of early stroke at 30 days was recorded in the self-expanding group (5.1% vs 0.6%; p=0.002).

Conclusion: The hemodynamic advantage of self-expanding valves does not translate into better clinical outcomes

In conclusion, in patients with a small aortic annulus undergoing TAVI, self-expanding valves provide a sustained hemodynamic advantage at five years, with lower gradients and a larger effective valve area. However, this benefit does not translate into a reduction in major clinical events or improved survival and is offset by a higher incidence of paravalvular leak and, particularly, permanent pacemaker implantation. These findings support an individualized selection of prosthesis type, balancing hemodynamic performance and clinical risk in each patient.

Original Title: Long-Term Clinical Outcomes of Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Replacement in Patients With Small Aortic Annulus.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

One-Year Results of ENCIRCLE: Percutaneous Mitral Valve Replacement in Patients Ineligible for Surgery or TEER

Symptomatic mitral regurgitation (MR) in patients who are not candidates for surgery or transcatheter edge-to-edge repair (TEER) remains a highly complex clinical scenario associated...

Can Coronary CT Angiography Replace Invasive Coronary Angiography in Pre-TAVI Coronary Assessment?

Coronary artery disease coexists in approximately half of patients undergoing transcatheter aortic valve implantation, making coronary assessment prior to the procedure essential. Invasive coronary...

Valve-in-Valve in Small Surgical Aortic Bioprostheses: Balloon-Expandable or Self-Expanding? Three-Year Results from the LYTEN Trial

Dysfunction of small surgical aortic bioprostheses represents a challenging scenario for transcatheter aortic valve replacement in the valve-in-valve setting, due to the higher incidence...

Can TAVI Be Safely Performed in Patients With Bicuspid Aortic Valve?

Bicuspid aortic valve (BAV) represents an anatomical challenge for transcatheter aortic valve replacement (TAVR) due to the frequent presence of elliptical annuli, fibroc calcific...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

One-Year Results of ENCIRCLE: Percutaneous Mitral Valve Replacement in Patients Ineligible for Surgery or TEER

Symptomatic mitral regurgitation (MR) in patients who are not candidates for surgery or transcatheter edge-to-edge repair (TEER) remains a highly complex clinical scenario associated...

Can Coronary CT Angiography Replace Invasive Coronary Angiography in Pre-TAVI Coronary Assessment?

Coronary artery disease coexists in approximately half of patients undergoing transcatheter aortic valve implantation, making coronary assessment prior to the procedure essential. Invasive coronary...

Valve-in-Valve in Small Surgical Aortic Bioprostheses: Balloon-Expandable or Self-Expanding? Three-Year Results from the LYTEN Trial

Dysfunction of small surgical aortic bioprostheses represents a challenging scenario for transcatheter aortic valve replacement in the valve-in-valve setting, due to the higher incidence...