New Balloon-Expandable Aortic Valve: 30-Day Outcomes in Patients with Small Aortic Annulus

As transcatheter aortic valve implantation (TAVI) continues to expand toward younger patients with longer life expectancy, factors such as valve hemodynamic performance, durability, and the feasibility of future reintervention become increasingly important. Patients with a small aortic annulus (SAA) undergoing TAVI often experience suboptimal outcomes, including higher transprosthetic gradients, increased prosthesis–patient mismatch (PPM), and early bioprosthetic valve failure (BVF). 

Nueva válvula aórtica balón-expandible: resultados a 30 días en pacientes con anillo aórtico pequeño

These outcomes may be influenced by transcatheter aortic valve design, particularly differences in leaflet position (supra-annular versus intra-annular) and overall valve architecture. However, currently available data on this topic remain conflicting.

The DurAVR transcatheter heart valve (THV; Anteris Technologies) is a novel balloon-expandable valve featuring a unique single-piece biomimetic leaflet design, unprecedented among currently available devices. Early experience from feasibility studies and first-in-human trials has demonstrated promising results.

The aim of this study was to report procedural, clinical, and hemodynamic outcomes at 30 days following TAVI in patients with SAA treated with the DurAVR valve.

Read also: TAVI in small aortic annulus: self-expanding or balloon-expandable valve in the long term?

This analysis, derived from early feasibility and first-in-human studies, included all patients with SAA (defined as an aortic annular area between 346 mm² and 452 mm²) treated with small-size DurAVR aortic valves. The mean aortic annular area, assessed by computed tomography (CT), was 404 ± 37 mm², with a mean annular diameter of 22.7 ± 1.0 mm. Thirty-day outcomes, including PPM assessment, were evaluated according to VARC-3 criteria, with independent adjudication of clinical events and post-implant echocardiographic analysis.

A total of 100 patients were analyzed. Mean age was 77.0 ± 7.3 years, and the majority were women (78%). The mean STS score was 4.7 ± 4.0%. Transfemoral access was used in 94% of cases.

Favorable 30-Day Hemodynamic Performance and Low Prosthesis–Patient Mismatch in Small Aortic Annulus

The overall technical success rate was 93%. At 30 days, device success was achieved in 91% of patients, with no reported deaths and a stroke rate of 2%. Echocardiographic hemodynamic assessment demonstrated a mean transprosthetic gradient of 8.2 ± 3.1 mmHg, a mean effective orifice area of 2.2 ± 0.3 cm², and a Doppler velocity index of 0.60 ± 0.10. The incidence of moderate or greater PPM was 3%, and no patient experienced more than mild paravalvular leak. The rate of new permanent pacemaker implantation was 6%.

Conclusion: DurAVR Balloon-Expandable Valve Shows High Device Success and Promising Short-Term Outcomes in Small Aortic Annulus

The balloon-expandable DurAVR aortic valve demonstrated high rates of technical and device success, along with favorable hemodynamic outcomes at 30 days, including a low incidence of PPM in patients with SAA. Further studies are needed to confirm its long-term durability.

Original Title: Thirty-day outcomes of a novel biomimetic balloon-expandable transcatheter heart valve in patients with small aortic annuli.

Reference: Ole De Backer et al EuroIntervention 2026;22:e -e160.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

Dr. Andrés Rodríguez
Dr. Andrés Rodríguez
Member of the Editorial Board of solaci.org

More articles by this author

Hemodynamic Outcomes of Edge-to-Edge Repair in Degenerative and Functional Mitral Regurgitation

Transcatheter edge-to-edge mitral valve repair (M-TEER) has become an established therapeutic option for mitral valve disease. Among the available techniques, M-TEER using the MitraClip...

SAPIEN 3 TAVI Durability: Ten-Year Follow-Up in Intermediate-Risk Patients

The durability of transcatheter bioprosthetic valves used in TAVI remains one of the key unanswered questions as indications continue to expand toward patients with...

Inflammation after TAVI: An Emerging Therapeutic Target?

Conduction disturbances and the need for permanent pacemaker implantation remain common complications following TAVI, with an incidence approaching 15%. Although they have traditionally been...

Coronary Obstruction During TAVI: A New Volumetric Index to Consider

Coronary obstruction during TAVI is an uncommon but potentially catastrophic complication, particularly in valve-in-valve procedures, in anatomies with small sinuses of Valsalva, low coronary...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

Is IVUS Always Necessary for Left Main Coronary Artery PCI?

Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery is a highly complex procedure because of the large amount of myocardium at...

Dual-Prep Registry: Atherectomy and IVL for Severe Coronary Calcification

Severe coronary calcification remains one of the most challenging scenarios in percutaneous coronary intervention (PCI). Although rotational or orbital atherectomy and intravascular lithotripsy (IVL)...

Hemodynamic Outcomes of Edge-to-Edge Repair in Degenerative and Functional Mitral Regurgitation

Transcatheter edge-to-edge mitral valve repair (M-TEER) has become an established therapeutic option for mitral valve disease. Among the available techniques, M-TEER using the MitraClip...