SOURCE XT: Results at 2 years of SAPIEN XT valve

Multicenter prospective study included 2688 patients with a mean age of 81.4 years and 20.5 EuroScore. The all-cause mortality at 2 years was 27.7% (31.5% SOURCE study). The incidence of stroke at 2 years was 7.7% and moderate to severe aortic regurgitation 7.3% and 0.2% respectively. There was a significant improvement in functional class and quality of life of patients. 

Conclusion 

The 2-year results of the SAPIEN XT prosthesis showed the evolution of the prosthesis relative to the previous generation. 

S. Windecker
2014-05-23

Title: 2-year outcomes from the SOURCE XT post approval study

More articles by this author

NOBORI II: Final 5-year results of drug-eluting stent with bio-absorbable polymer

This study evaluated the performance of Nobori biolimus bio-absorbable polymer stent in real-world patients. A total of 3067 consecutive patients followed up to 5...

TRYTON dedicated bifurcation stent in left main coronary artery

TRYTON is a cobalt chromium device specifically dedicated for bifurcation lesions to be implanted in the side branch. Circumflex artery is the major lateral...

UK TAVI Registry: Long-term results of TAVI in the UK

This record has been created in order to evaluate the results of percutaneous aortic valve replacement in the UK and currently includes more than...

DISCOVER Trial: Results at one year of the new nonmetallic percutaneous aortic valve

Direct Flow Medical prosthesis is a nonmetallic, repositionable, recaptured valve (even after posts dilate), that does not require a pacemakers use during both implantation...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Coronary access after TAVI with fourth- and fifth-generation Evolut valves: the EPROMPT-CA study

The expansion of transcatheter aortic valve implantation (TAVI) toward younger and lower-risk patients has increased the relevance of post-procedural coronary access. In this context,...

Morpheus Global Registry: Safety and efficacy of the long tapered BioMime™ Morph stent in complex coronary lesions

Percutaneous coronary intervention in long coronary lesions continues to represent a technical and clinical challenge, in which the use of conventional cylindrical stents may...

TEER plus optimal medical therapy versus medical therapy alone in functional mitral regurgitation

Mitral regurgitation (MR) is a highly prevalent valvular heart disease that, in advanced stages and when left untreated, is associated with reduced quality of...