TAVR: The Need for a Pacemaker Is Associated with Mortality

Courtesy of Dr. Carlos Fava.

 

TAVR: The Need for a Pacemaker

After a transcatheter aortic valve replacement (TAVR), the incidence of permanent pacemaker (PPM) implantation ranges from 6% to 30% in different studies, depending on the valve type used. This is due to trauma, ischemia, haemorrhage, and atrioventricular node and infranodal tissue oedema, provoking ventricular dyssynchrony similar to that caused by complete left bundle branch block. The evolution of patients requiring permanent pacemaker after TAVR has not been fully studied.

 

This study included 9785 patients from 229 hospitals; 651 (6.65%) of these subjects received a permanent pacemaker.

 

Patients receiving a permanent pacemaker were more frequently men with a higher STS predicted risk of mortality score (7.3% vs. 6.7%; p = 0.004), who received aortic valvuloplasty less often and presented more conduction defects in the baseline echocardiogram.

 

During the procedure, patients requiring a permanent pacemaker received larger valves, with higher oversizing. Mean time between valve replacement and permanent pacemaker implantation was three days.

 

Self-expanding valves (CoreValve) required the implantation of permanent pacemakers more frequently than balloon-expandable valves (E. Sapiens). Extreme-risk or inoperable patients required a permanent pacemaker more frequently than high-risk patients. Hospital stays were longer for patients requiring a PPM.

 

At a year, the need for a permanent pacemaker was associated with an increase in mortality (24.1% vs. 19.6%; hazard ratio [HR]: 1.31; 95% confidence interval [CI]: 1.09 to 1.58) and an increase in a composite of mortality and heart failure (37.3% vs. 28.5%; HR: 1.33; 95% CI: 1.13 to 1.56).

 

The following were predictors of the need for permanent pacemaker implantation after TAVR at 30 days:

  • age;
  • prior conduction defect;
  • aortic valve area ≤0.75 cm2;
  • use of self-expanding valves.

 

Conclusion

The need for a pacemaker is a common complication following TAVR, and it is associated with higher mortality and hospitalization due to heart failure at one year.

 

Editorial

Prior studies argued that permanent pacemaker implantation did not affect outcomes. This study, however, proves the opposite: it is associated to a hard event, mortality, and a higher need for hospitalization due to heart failure. This also increases healthcare costs.

 

The upcoming challenge lies in the development of devices that lower the need for a permanent pacemaker while maintaining or improving current performance.

 

Courtesy of Dr. Carlos Fava. Buenos Aires Favaloro Foundation, Argentina.

 

Original title: Incidence, Predictors, and Outcomes of Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement. Analysis from the U.S. Society of Thoracic Surgeons/American College of Cardiology TVT Registry.

Reference: Opeyemi O. FadaHunsi, et al. J Am Coll Cardiol Intv 2016;9:2189-99.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Hemodynamic Outcomes of Edge-to-Edge Repair in Degenerative and Functional Mitral Regurgitation

Transcatheter edge-to-edge mitral valve repair (M-TEER) has become an established therapeutic option for mitral valve disease. Among the available techniques, M-TEER using the MitraClip...

SAPIEN 3 TAVI Durability: Ten-Year Follow-Up in Intermediate-Risk Patients

The durability of transcatheter bioprosthetic valves used in TAVI remains one of the key unanswered questions as indications continue to expand toward patients with...

Inflammation after TAVI: An Emerging Therapeutic Target?

Conduction disturbances and the need for permanent pacemaker implantation remain common complications following TAVI, with an incidence approaching 15%. Although they have traditionally been...

Coronary Obstruction During TAVI: A New Volumetric Index to Consider

Coronary obstruction during TAVI is an uncommon but potentially catastrophic complication, particularly in valve-in-valve procedures, in anatomies with small sinuses of Valsalva, low coronary...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

Is IVUS Always Necessary for Left Main Coronary Artery PCI?

Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery is a highly complex procedure because of the large amount of myocardium at...

Dual-Prep Registry: Atherectomy and IVL for Severe Coronary Calcification

Severe coronary calcification remains one of the most challenging scenarios in percutaneous coronary intervention (PCI). Although rotational or orbital atherectomy and intravascular lithotripsy (IVL)...

Hemodynamic Outcomes of Edge-to-Edge Repair in Degenerative and Functional Mitral Regurgitation

Transcatheter edge-to-edge mitral valve repair (M-TEER) has become an established therapeutic option for mitral valve disease. Among the available techniques, M-TEER using the MitraClip...