ABSORB III: after 3 Years, the Bioresorbable Scaffold is Still a Disappointment

Courtesy of the SBHCI.

The 3-year outcomes of the ABSORB III trial, which randomized 2008 patients 2:1 to an everolimus eluting bioresorbable scaffold (1322 patients) vs. a metallic stent with permanent everolimus eluting polymer (686 patients), was published with low profile and great disappointment.

ABSORB III: a 3 años continua la desilusión de la plataforma bioabsorbible

Primary end-point, a composite of target vessel failure, occurred in 13.4% of patients receiving the bioresorbable scaffold vs. 10.4% of patients receiving the Xience stent (p=0.06) at three-year follow up.


Read also: Absorb IV: Bioresorbable Scaffolds with an Optimized Implantation Technique”.


There was a significant increase in myocardial infarction rate associated to the target vessel lesion (8.6% vs. 5.9%; p=0.03), and an increase in definite/ thrombosis (2.3% vs. 0.7%; p=0.01) in the Absorb group.

 

Conclusion

At three-year follow up, the events rate was higher with the Absorb bioresorbable scaffold due to an increase in infarction rate associated to target vessel failure and definite/probable thrombosis.

 

Courtesy of the SBHCI.

 

Original title 3-Year Outcomes From a Randomized Trial of a Bioresorbable Scaffold vs a Metallic DES in Patients With Coronary Artery Disease.

Presenter: Stephen G. Ellis.

 

ABSORB-III


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Coronary Artery Disease in Aortic Stenosis: CABG + SAVR vs. TAVR + PCI: Data from Spanish Centers

Multiple randomized studies have shown comparable or superior efficacy of transcatheter aortic valve replacement (TAVR) vs. coronary artery bypass graft (CABG).  However, many of...

Evolution of Small Balloon-Expandable Valves

Small aortic rings (20 mm) have posed a significant challenge for both surgery and transcatheter aortic valve implantation (TAVI) due to their association with an...

TCT 2024 | FAVOR III EUROPA

The study FAVOR III EUROPA, a randomized trial, included 2,000 patients with chronic coronary syndrome, or stabilized acute coronary syndrome, and intermediate lesions. 1,008...

TCT 2024 – ECLIPSE: Randomized Study of Orbital Atherectomy vs Conventional PCI in Severely Calcified Lesions

Coronary calcification is associated with stent under-expansion and increased risk of both early and late adverse events. Atherectomy is an essential tool for uncrossable...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Severe Tricuspid Regurgitation: Surgical vs. Transcatheter Edge-to-Edge Repair

While highly prevalent, tricuspid regurgitation is a notably undertreated valvulopathy. Its progression has been associated with higher mortality and significant disability. According to the...

ACCESS-TAVI: Comparing Post TAVR Vascular Closure Devices

Transcatheter aortic valve replacement (TAVR) is a well-established option to treat elderly patients with severe symptomatic aortic valve stenosis. Technical advances and device development...

Endovascular Treatment of Iliofemoral Disease for the Improvement of Heart Failure with Preserved Ejection Fraction

Peripheral artery disease (PAD) is a significant risk factor in the development of difficult-to-treat conditions, such as heart failure with preserved ejection fraction (HFpEF)....