More Evidence For MitraClip in High Risk Patients with Severe Tricuspid Regurgitation

Courtesy of Dr. Carlos Fava.

Tricuspid regurgitation (TR) has a negative impact in the long run. Several reports have shown that, in high risk inoperable patients, transcatheter edge-to-edge valve repair with MitraClip is feasible, safe and has good results, but there is still a long way to go.

The present study looked at 24 consecutive patients with severe TR undergoing transcatheter edge-to-edge repair with MitraClip.

 

Primary end point was TR grade and functional class at 12 months, while Secondary end point was 6-minute walk distance, NT-pro-BNP level, quality of life (MLHFQ) and right ventricle echocardiographic parameters.

 

Mean age was 79, nearly all patients were functional class III-IV, STS mortality was 6%. In addition, 16 patients received MitraClip in the mitral valve in the same procedure. Left ventricle ejection fraction was 46±15% and right ventricle ejection fraction was 38±8%, TAPSE 16±4 mm.


Read also: MitraClip in Severe MR: 5 Year Mortality Rate Similar to Surgery.


Procedural success, defined as TR <2+, was achieved in 96% of cases.

 

At one year, 9 patients died: 4 because of final stage of cardiac failure, 2 for sepsis, 1 for AMI and 2 for unknown reasons. 2 patients required reintervention for severe TR, but none required surgery. All patients showed significantly improved functional class, 6 minute walk test outcome, NT-pro-BNP and quality of life. Right ventricular ejection fraction and TAPSE showed no improvement.

 

Conclusion

Preliminary clinical and echocardiographic results of this study are promising and encourage further study of the use of transcatheter edge-to-edge repair in inoperable patients with severe TR.

 

Courtesy of Dr. Carlos Fava.

 

Original title: One-year results of transcatheter treatment of severe tricuspid regurgitation using the edge-to-edge repair technique.

Reference: Daniel Braun, et al. EuroIntervention 2018;14:e413-e415


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Transradial Aortic Valvuloplasty: Is Minimalism Worth It?

Balloon aortic valvuloplasty (BAV) has historically been used either as a bridge strategy, an assessment tool, or even palliative treatment in severe aortic stenosis...

Atrial Fibrillation After Percutaneous Patent Foramen Ovale Closure: Cohort Study with Continuous Implantable Cardiac Monitoring

Atrial fibrillation (AF) is a recognized complication following percutaneous closure of a patent foramen ovale (PFO), with reported incidences of up to 30% during...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Coronary Perforations and Use of Covered Stents: Safe and Effective Long-Term Strategy?

Coronary perforations remain one of the most serious complications of percutaneous coronary intervention (PCI), especially in cases of Ellis ruptures type III. In these...

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....