TCT 2018 | NEOPRO: A Registry for Acurate neo and Evolut PRO

The purpose of this registry was to compare short-term clinical events and echocardiographic findings in two self-expanding valves used with transfemoral access, Acurate neo and Evolut PRO.

NEOPRO: registro entre Acurate neo y Evolut PROThe registry included a retrospective follow-up of 1551 patients, among whom 1263 received an Acurate neo valve and 288 received an Evolut Pro valve.

 

The procedural success rates according to VARC-2 criteria were high, 90.5% vs. 91.6% (p = 0.7), and the rates of occurrence of moderate-to-severe paravalvular aortic regurgitation were 7.3% vs. 5.7% (p = 0.5), respectively. There were no instances of coronary occlusion in the whole cohort and the rates of permanent pacemaker implantation were low and similar, around 12%.

 

The rates of bleeding and vascular complications were higher among patients in the Acurate neo arm, but this difference disappeared after adjusting these populations according to their clinical characteristics.

 

Original title: Nonrandomized Comparison of Two Transcatheter Heart Valve in Patients with Severe Aortic Stenosis.

Presenter: Azeem Latib.

 


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

UNICORN Technique to Prevent Coronary Obstruction During TAVI: Initial Results From a Multicenter Study

Coronary obstruction is an uncommon but potentially catastrophic complication of transcatheter aortic valve implantation (TAVI), particularly in valve-in-valve procedures, TAV-in-TAV interventions, or in patients...

Hemodynamic Outcomes of Edge-to-Edge Repair in Degenerative and Functional Mitral Regurgitation

Transcatheter edge-to-edge mitral valve repair (M-TEER) has become an established therapeutic option for mitral valve disease. Among the available techniques, M-TEER using the MitraClip...

SAPIEN 3 TAVI Durability: Ten-Year Follow-Up in Intermediate-Risk Patients

The durability of transcatheter bioprosthetic valves used in TAVI remains one of the key unanswered questions as indications continue to expand toward patients with...

Inflammation after TAVI: An Emerging Therapeutic Target?

Conduction disturbances and the need for permanent pacemaker implantation remain common complications following TAVI, with an incidence approaching 15%. Although they have traditionally been...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

UNICORN Technique to Prevent Coronary Obstruction During TAVI: Initial Results From a Multicenter Study

Coronary obstruction is an uncommon but potentially catastrophic complication of transcatheter aortic valve implantation (TAVI), particularly in valve-in-valve procedures, TAV-in-TAV interventions, or in patients...

Supera vs. Eluvia at 3 Years in Severely Calcified Femoropopliteal Lesions

Severe calcification remains one of the main predictors of restenosis and the need for repeat revascularization following endovascular treatment of femoropopliteal disease. In this...

Is IVUS Always Necessary for Left Main Coronary Artery PCI?

Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery is a highly complex procedure because of the large amount of myocardium at...